#meta full request: /START_COUNTER/start_parms:0:default:2013-01-17_19-02-27 #meta variation: default #meta created: 2013-01-17 19:02:27 #meta run range: 0 - inf. #meta author: anonymous # # # START COUNTER data base of constants used # # Start counter timeing resolution 300ps # Start counter number of photons per MeV # attenuation length in cm # effective speed of light in cm/ns # time window for two hit resolution in ns # maximum number of hits per readout channel # threshold in MeV # light guide length in cm # ? # ? #& START_SIGMA START_PHOTONS_PERMEV START_ATTEN_LENGTH START_C_EFFECTIVE START_TWO_HIT_RESOL START_MAX_HITS START_THRESH_MEV START_LIGHT_GUIDE START_ANGLE_COR START_BENT_REGION 0.3 200.; 150. 15. 25. 100 0.150 0. 1.038 39.465