Radiation levels in the Hall D tagger area during the May 2014 beam delivery

Document #:
GlueX-doc-2508-v1
Document type:
Hall D Note
Submitted by:
Alexandre Deur
Updated by:
Alexandre Deur
Document Created:
30 May 2014, 14:34
Contents Revised:
30 May 2014, 14:34
Metadata Revised:
30 May 2014, 14:34
Viewable by:
  • Public document
Modifiable by:

Quick Links:
Latest Version

Other Versions:
GlueX-doc-2508-v2
24 Jul 2014, 07:22
Abstract:
We discuss the doses and dose rates seen in the Hall D tagger area during the May 2014 beam delivery. The averaged dose rate with the pulse beam tuned through the tagger was from 2 to 4 rem/h. For a 3 A continuous beam of similar quality (beam scrapping was evident on the tagger dump viewer during this period), this would represent from about 130 to 260 rem/h.