GlueX Logo

GlueX Experiment Document 439-v3

DocDB Home ]  [ Portal Home ]  [ Search ] [ Last 20 Days ] [ List Authors ] [ List Topics ] [ List Events ]

BCAL Radiation Length Calculations

Document #:
GlueX-doc-439-v3
Document type:
Technical Note
Submitted by:
Zisis Papandreou
Updated by:
Zisis Papandreou
Document Created:
28 Feb 2005, 09:15
Contents Revised:
17 Apr 2005, 21:55
Metadata Revised:
17 Apr 2005, 21:56
Viewable by:
  • Public document
Modifiable by:
  • Same as Viewable by

Quick Links:
Latest Version

Other Versions:
GlueX-doc-439-v5
18 Jun 2007, 17:00
GlueX-doc-439-v4
18 Jun 2007, 10:11
GlueX-doc-439-v2
28 Feb 2005, 09:28
GlueX-doc-439-v1
28 Feb 2005, 09:21
Abstract:
Analytical calculations of the radiation length for the Barrel Calorimeter of the GlueX Project are presented. These show that the full thickness radiation length ranges from 18-20 X_0 depending on the thickness of the aluminum backing plate and the analytical formalism used.
Files in Document:
Notes and Changes:
This version has a small correction to the calculation of the effective Z and A for the Pb/SciFi/Glue mixture, leading to more stable values of Xo for the three formalisms.
DocDB Home ]  [ Portal Home ]  [ Search ] [ Last 20 Days ] [ List Authors ] [ List Topics ] [ List Events ]