Line 19: | Line 19: | ||
* '''Turn off'''. Turns off refrigerator and lets the target warm up. | * '''Turn off'''. Turns off refrigerator and lets the target warm up. | ||
− | To turn on the target, use ''Empty'' or ''Fill'' buttons. To turn the target off use ''Turn off'' button. | + | To turn on the target, use ''Empty'' or ''Fill'' buttons. It takes about 6h to cool the target from room temperature. To turn the target off use ''Turn off'' button. |
Operation manual for the target can be found [https://halldweb.jlab.org/DocDB/0026/002682/001/Operation_HallD_Cryotarget_Rev1.pdf here]. | Operation manual for the target can be found [https://halldweb.jlab.org/DocDB/0026/002682/001/Operation_HallD_Cryotarget_Rev1.pdf here]. | ||
− | '''Do not change the target status without calling first an expert.''' | + | <!--'''Do not change the target status without calling first an expert.'''--> |
== Interlocks == | == Interlocks == | ||
Line 30: | Line 30: | ||
If such event happens or if the target warms up, the target should not be damaged. However, beam time will be lost. '''Call an expert immediately''' | If such event happens or if the target warms up, the target should not be damaged. However, beam time will be lost. '''Call an expert immediately''' | ||
+ | |||
+ | == In case of problem with remotely controlling the target == | ||
+ | If the target control freezes, there are several ways to restore them, [https://logbooks.jlab.org/entry/4116279 described here]. | ||
== Expert personnel == | == Expert personnel == | ||
Line 42: | Line 45: | ||
! width=200px | Name !! width=100px | Extension !! Date of qualification | ! width=200px | Name !! width=100px | Extension !! Date of qualification | ||
|- | |- | ||
− | | Alexandre Deur | + | | Alexandre Deur || align=center | Office: 757-269-7526 / Cell: 757-871-5931 || align=center | June 12, 2014 |
|- | |- | ||
− | |||
− | |||
| Chris Keith (Target group leader) || align=center | Office: 757-269-5878 / Cell 757-746-9277 || align=center | June 12, 2014 | | Chris Keith (Target group leader) || align=center | Office: 757-269-5878 / Cell 757-746-9277 || align=center | June 12, 2014 | ||
|- | |- |
Latest revision as of 06:40, 8 May 2025
Contents
The Cryogenic Target
The Hall D cryogenic target consists of a tapered kapton target cell of 29.9 cm length, 2 cm diameter, a vacuum chamber, a pulse tube refrigerator, a compressor and its water cooling system, a gas manifold and panel, the electronic controls (PLC logic), a support cart and safety storage tanks. The figure below shows some of its main components.
The cell can be filled with liquid H2 (physics run) or gas H2 (empty run). It has a 130 um kapton wall and 75 um entrance and exit kapton windows.
When filled with LH2, the operating pressure and temperature are P=18 psia and T=17K.
Routine Operation
There are 3 routine operations:
- Empty target. Refrigerator is turned on and cell is cooled to temperature for cold H2 gas.
- Fill target with LH2. Refrigerator is turned on and cell is cooled to temperature for liquid H2.
- Turn off. Turns off refrigerator and lets the target warm up.
To turn on the target, use Empty or Fill buttons. It takes about 6h to cool the target from room temperature. To turn the target off use Turn off button.
Operation manual for the target can be found here.
Interlocks
Safety interlocks protect the target if the temperature decreases below 16K or the pressure decreases 16 psia.
If such event happens or if the target warms up, the target should not be damaged. However, beam time will be lost. Call an expert immediately
In case of problem with remotely controlling the target
If the target control freezes, there are several ways to restore them, described here.
Expert personnel
The individuals responsible for checking that the cryogenic target is ready to take data and setting its operating parameters are shown in following table. Hall D contacts should be called first Problems with normal operation of the cryogenic target should be referred to those individuals and any changes to their settings must be approved by them. Additional experts may be trained by the system owner and their name and date added to this table.
Name | Extension | Date of qualification |
---|---|---|
Alexandre Deur | Office: 757-269-7526 / Cell: 757-871-5931 | June 12, 2014 |
Chris Keith (Target group leader) | Office: 757-269-5878 / Cell 757-746-9277 | June 12, 2014 |
James Brock (Target group) | Office: 757-269-7860 / Cell 757-871-5374 | June 12, 2014 |
Chris Carlin (For computer control issues) | Office: 757-269-5971 / Cell 757-559-1269 | June 12, 2014 |