Difference between revisions of "Solenoid Expert"
From Hall D Ops Wiki
(→Procedures: signed documents) |
(→Technical Information) |
||
(7 intermediate revisions by the same user not shown) | |||
Line 38: | Line 38: | ||
*Hall-D Solenoid Commissioning Procedure: [https://misportal.jlab.org/jlabDocs/document.seam?id=81871 D000000402P002] | *Hall-D Solenoid Commissioning Procedure: [https://misportal.jlab.org/jlabDocs/document.seam?id=81871 D000000402P002] | ||
− | |||
− | + | = Technical Information = | |
− | === [[solenoid_expert_magnet | Magnet ]] === | + | == Magnet == |
+ | * [http://argus.phys.uregina.ca/cgi-bin/private/DocDB/ShowDocument?docid=2378 Post-construction description: GlueX note 2378] | ||
+ | * Magnetic field | ||
+ | ** [https://www.jlab.org/Hall-D/solenoid/field/calculations/calculations.html Field calculations using POISSON ] | ||
+ | ** [https://www.jlab.org/Hall-D/solenoid/field/calculations/inductance.html Inductance - calculations and measurements (2014-2015) ] | ||
+ | ** [[Solenoid Magnetic Field | Field Measurements from 2013 ]] | ||
+ | ** [[Solenoid_Magnetic_Field]] | ||
+ | ** [https://halldweb.jlab.org/wiki/index.php/Solenoid_Magnetic_Field Field] | ||
+ | * [[solenoid_expert_magnet | Magnet ]] | ||
+ | == Controls == | ||
+ | * [[solenoid_expert_plc | Programmable Logic Control (PLC) ]] | ||
+ | * [[solenoid_expert_pxi | PXI Fast DAQ System ]] | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
== Old Wiki Page == | == Old Wiki Page == | ||
− | [https:// | + | [https://halldweb.jlab.org/wiki/index.php/Superconducting_Solenoid https://halldweb1.jlab.org/wiki/index.php/Superconducting_Solenoid] |
Latest revision as of 11:55, 19 January 2017
Contents
Operations
Wiki Instructions
Operational Safety Procedures (OSP) : signed documents
- Hall D Solenoid Magnet - Cryogenic Operations: ENG-12-19709-OSP
- Hall D Solenoid Power Supply Test and Maintenance: -13-21781-OSP
- Hall D Solenoid Powered Operations OSP: FEL-13-22021-OSP
Other Procedures and Checklists : signed documents
- Solenoid Cooldown Checklists: D000000402-P003 Rev A
- Solenoid Vacuum System Controls Check Procedure: D000000402P004
- Hall D Solenoid System Hi-Pot Procedure: D000000402P006 RevA
- Solenoid Voltage Tap Check List: D000000402-P010
- Hall D Solenoid Pre Power-Up Checklists: D000000402P007
- Hall D Solenoid Magnet Power Supply Maintenance Turn-on Checklist: D000001611P000 Rev A
- Hall D Solenoid Magnet Power Supply Internal Interlock Checklist: D000001611P001 Rev B
- Ground Fault Detector Rheostat Setting Procedure: D000000402P011
- Hall D Solenoid System Hi-Pot Procedure: D000000402P006 RevA
- Solenoid Quench Detector Tuning Procedure: D000000402P005
- Hall-D Solenoid Commissioning Procedure: D000000402P002
Technical Information
Magnet
- Post-construction description: GlueX note 2378
- Magnetic field
- Magnet
Controls
Old Wiki Page
https://halldweb1.jlab.org/wiki/index.php/Superconducting_Solenoid