Difference between revisions of "Standard Production Running Conditions"
From Hall D Ops Wiki
Line 9: | Line 9: | ||
| Beam Profiler || in || in | | Beam Profiler || in || in | ||
|- | |- | ||
− | | Active Collimator optimal coordinates || x = -0. | + | | Active Collimator optimal coordinates || x = -0.9 mm, y = 0.0 mm || same as polarized |
|- | |- | ||
| Collimator || 3.4 mm || 3.4 mm | | Collimator || 3.4 mm || 3.4 mm |
Revision as of 17:08, 31 March 2016
Item | Polarized Beam | Unpolarized Beam |
---|---|---|
Beam Current | 200 nA | 200 nA |
Radiator | 20 micron diamond, JD70-118 | amorphous, 3×10-4 |
Beam Profiler | in | in |
Active Collimator optimal coordinates | x = -0.9 mm, y = 0.0 mm | same as polarized |
Collimator | 3.4 mm | 3.4 mm |
TPol target | Be 750 μm | Be 750 μm |
Pair Spect. Convertor | retracted | retracted |
Pair Spect. Magnet Current | 991 A | 991 A |
GlueX Solenoid | 1200 A | 1200 A |
TAC | retracted | retracted |