Difference between revisions of "Standard Production Running Conditions"
From Hall D Ops Wiki
(→Spring 2017 Draft not yet updated) |
|||
Line 1: | Line 1: | ||
− | === Spring 2017 | + | === Spring 2017 === |
Line 6: | Line 6: | ||
! Item !! Polarized Beam !! Unpolarized Beam | ! Item !! Polarized Beam !! Unpolarized Beam | ||
|- | |- | ||
− | | Beam Current || | + | | Beam Current || 100 nA || 150 nA |
|- | |- | ||
− | | BPM (IPM5C11B) optimal coordinates || x = -1.6 mm, y = +1.0 mm || same | + | | BPM (IPM5C11B) optimal coordinates || x = -1.6 mm, y = +1.0 mm || same |
|- | |- | ||
− | | Tagger Quadrupole (MQPAD00) Current || | + | | Tagger Quadrupole (MQPAD00) Current || -4.2 A || same |
|- | |- | ||
− | | Radiator || | + | | Radiator || 58 micron diamond, JD70-100 || amorphous, 3×10<sup>-4</sup> |
|- | |- | ||
| Beam Profiler || retracted || retracted | | Beam Profiler || retracted || retracted | ||
|- | |- | ||
− | | Active Collimator optimal coordinates || x = | + | | Active Collimator (Inner) optimal coordinates || x = 0.0±0.1 mm, y = -0.3±0.2 mm || same |
|- | |- | ||
− | | Collimator || | + | | Collimator || 5.0 mm || same |
|- | |- | ||
− | | TPol target || Be 75 μm || | + | | TPol target || Be 75 μm || same |
|- | |- | ||
− | | Pair Spect. Convertor || retracted || | + | | Pair Spect. Convertor || retracted || same |
|- | |- | ||
− | | Pair Spect. Magnet Current || | + | | Pair Spect. Magnet Current (set point) || 910 A || same |
|- | |- | ||
| GlueX Solenoid || 1200 A || 1200 A | | GlueX Solenoid || 1200 A || 1200 A | ||
Line 30: | Line 30: | ||
| TAC || retracted || retracted | | TAC || retracted || retracted | ||
|} | |} | ||
− | |||
=== Spring 2016 === | === Spring 2016 === |
Revision as of 09:47, 24 February 2017
Spring 2017
Item | Polarized Beam | Unpolarized Beam |
---|---|---|
Beam Current | 100 nA | 150 nA |
BPM (IPM5C11B) optimal coordinates | x = -1.6 mm, y = +1.0 mm | same |
Tagger Quadrupole (MQPAD00) Current | -4.2 A | same |
Radiator | 58 micron diamond, JD70-100 | amorphous, 3×10-4 |
Beam Profiler | retracted | retracted |
Active Collimator (Inner) optimal coordinates | x = 0.0±0.1 mm, y = -0.3±0.2 mm | same |
Collimator | 5.0 mm | same |
TPol target | Be 75 μm | same |
Pair Spect. Convertor | retracted | same |
Pair Spect. Magnet Current (set point) | 910 A | same |
GlueX Solenoid | 1200 A | 1200 A |
TAC | retracted | retracted |
Spring 2016
Item | Polarized Beam | Unpolarized Beam |
---|---|---|
Beam Current | 160 nA | 200 nA |
BPM (IPM5C11B) optimal coordinates | x = -1.6 mm, y = +1.0 mm | same as polarized |
Tagger Quadrupole (MQPAD00) Current | 0 A | 0 A |
Radiator | 20 micron diamond, JD70-119 | amorphous, 3×10-4 |
Beam Profiler | retracted | retracted |
Active Collimator optimal coordinates | x = -0.9 mm, y = 0.0 mm | same as polarized |
Collimator | 3.4 mm | 3.4 mm |
TPol target | Be 75 μm | Be 75 μm |
Pair Spect. Convertor | retracted | retracted |
Pair Spect. Magnet Current | 991 A | 991 A |
GlueX Solenoid | 1200 A | 1200 A |
TAC | retracted | retracted |