− | + | The Forward Drift Chamber (FDC) is a 12,672 channel system consisting | |
− | The | + | of four packages, each having six chambers (cells). |
− | The | + | Each chamber has a wire plane sandwiched between two |
− | + | cathodes consisting of readout strips. The chambers within a package | |
+ | have independent gas volumes, but are separated with a flexible mylar membrane. | ||
+ | Positive (up to 2300V) and negative (up to 500V) HV is applied on the | ||
+ | sense and field wires respectively with currents | ||
+ | not exceeding 10 $\mu $A per HV channel. | ||
+ | The detector (including cables) emits a total power of about 1500~Watt, | ||
+ | of which about 900~Watt inside the magnet, | ||
+ | due to the LV applied on the detector pre-amplifieres; | ||
+ | a cooling system using Fluorinert is used to keep the temperature on the | ||
+ | pre-amplifiers below ~50$^0$~C. | ||