Difference between revisions of "LED Run Procedure"

From Hall D Ops Wiki
Jump to: navigation, search
 
Line 4: Line 4:
 
# Stop the rcGUI if there’s anything running, then press "STOP" on rcm GUI to change configuration.
 
# Stop the rcGUI if there’s anything running, then press "STOP" on rcm GUI to change configuration.
 
# Turn on DIRC LED pulser at desired rate and turn on DIRC HV via CSS GUIs (if not already done).  
 
# Turn on DIRC LED pulser at desired rate and turn on DIRC HV via CSS GUIs (if not already done).  
# On rcm GUI, change “RUN” to EXPERT and change “SETUP” to hd_all.tsg_dirc_tof12
+
# On rcm GUI, change “RUN” to EXPERT and change “SETUP” to '''hd_all.tsg_dirc_tof12'''
 
#* Note: use the config file with lower case dirc_tof which only includes DIRC and TOF crates in the readout
 
#* Note: use the config file with lower case dirc_tof which only includes DIRC and TOF crates in the readout
 
# On rcm GUI, change “CONFIG” to DIRC_LED.conf. Then press “START” to start the rcGUI.
 
# On rcm GUI, change “CONFIG” to DIRC_LED.conf. Then press “START” to start the rcGUI.

Latest revision as of 02:16, 17 December 2019

(Last updated on 4/16/19)

  1. Stop the rcGUI if there’s anything running, then press "STOP" on rcm GUI to change configuration.
  2. Turn on DIRC LED pulser at desired rate and turn on DIRC HV via CSS GUIs (if not already done).
  3. On rcm GUI, change “RUN” to EXPERT and change “SETUP” to hd_all.tsg_dirc_tof12
    • Note: use the config file with lower case dirc_tof which only includes DIRC and TOF crates in the readout
  4. On rcm GUI, change “CONFIG” to DIRC_LED.conf. Then press “START” to start the rcGUI.
  5. Find the CRATE_ROCDIRC terminal and be ready to monitor it.
  6. On the rcm GUI, click the DAQmon button on the bottom right to monitor the scalers and FPGA temperatures.
  7. On rcGUI, go through the normal procedure of “Configure”, “Download” and “Prestart”.
    • After pressing “Prestart” the FPGA temperatures and scalers should begin to appear on the DAQmon GUI. Check that temperatures are nominal and that hits are seen in the scalers.
  8. On rcGUI, press the "Start" button to begin the run and start collecting triggers.