Difference between revisions of "Level-1 Trigger Shift"
From Hall D Ops Wiki
Line 31: | Line 31: | ||
Currently, there are following main triggers used in data production: | Currently, there are following main triggers used in data production: | ||
− | {|border=" | + | {|border="1" cellpadding="5" cellspacing="10" align="left" |
|- | |- | ||
! Trigger Type | ! Trigger Type | ||
! Trigger Bit (starting from 1) | ! Trigger Bit (starting from 1) | ||
|- | |- | ||
− | | FCAL | + | | FCAL + 0.5 BCAL > 0.5 GeV |
| 1 | | 1 | ||
|- | |- | ||
− | | BCAL | + | | BCAL > 1.1 GeV |
| 3 | | 3 | ||
|- | |- |
Revision as of 12:21, 12 February 2017
Contents
Configuration for Production Runs
Production data is taken with the following configuration, which has to be selected at the RCM Run Config GUI:
RUN: | EXPERT |
SETUP: | hd_all.tsg |
CONFIG: | FCAL_BCAL_PS_m9.conf (main production mode) or |
FCAL_BCAL_PS_m10.conf (debug mode, readout raw samples for FADCs 250 and 125) |
Trigger Types
Currently, there are following main triggers used in data production:
Trigger Type | Trigger Bit (starting from 1) |
---|---|
FCAL + 0.5 BCAL > 0.5 GeV | 1 |
BCAL > 1.1 GeV | 3 |
PS | 4 |
Main Triggers used in data production
TS Front Pannel Triggers
Trigger Monitor
Trigger Rates for Production Runs
Name | Extension | Date of qualification |
---|---|---|
Alexander Somov | 269-5553 | June 20, 2015 |