Level-1 Trigger Shift

From Hall D Ops Wiki
Revision as of 12:28, 12 February 2017 by Somov (Talk | contribs)

Jump to: navigation, search

Configuration for Production Runs

Production data is taken with the following configuration, which has to be selected at the RCM Run Config GUI:


RUN: EXPERT
SETUP: hd_all.tsg
CONFIG: FCAL_BCAL_PS_m9.conf (main production mode) or
FCAL_BCAL_PS_m10.conf (debug mode, readout raw samples for FADCs 250 and 125)


caption



Trigger Types

Currently, there are following main (GTP) triggers used in data production:


Trigger Type Trigger Bit (starting from 1)
FCAL + 0.5 BCAL > 0.5 GeV 1
BCAL > 1.1 GeV 3
PS 4



Main Triggers used in data production

TS Front Pannel Triggers

Trigger Monitor

Trigger Rates for Production Runs

Slot Address
3 0x180000
4 0x200000
5 0x280000
6 0x300000
7 0x380000
8 0x400000
9 0x480000
10 0x500000
13 0x680000
14 0x700000
15 0x780000
16 0x800000
17 0x880000
18 0x900000
19 0x980000
20 0xA00000
21 0xA80000



Table: Expert personnel for the Level 1 Trigger
Name Extension Date of qualification
Alexander Somov 269-5553 June 20, 2015