Level-1 Trigger Shift

From Hall D Ops Wiki
Revision as of 12:29, 12 February 2017 by Somov (Talk | contribs)

Jump to: navigation, search

Configuration for Production Runs

Production data is taken with the following configuration, which has to be selected at the RCM Run Config GUI:


RUN: EXPERT
SETUP: hd_all.tsg
CONFIG: FCAL_BCAL_PS_m9.conf (main production mode) or
FCAL_BCAL_PS_m10.conf (debug mode, readout raw samples for FADCs 250 and 125)


caption



Trigger Types

Currently, there are following main (GTP) triggers used in data production:


Trigger Type Trigger Bit (starting from 1)
FCAL + 0.5 BCAL > 0.5 GeV 1
BCAL > 1.1 GeV 3
PS 4


Slot Address
3 0x180000
4 0x200000
5 0x280000
6 0x300000
7 0x380000
8 0x400000
9 0x480000
10 0x500000
13 0x680000
14 0x700000
15 0x780000
16 0x800000
17 0x880000
18 0x900000
19 0x980000
20 0xA00000
21 0xA80000

Main Triggers used in data production

TS Front Pannel Triggers

Trigger Monitor

Trigger Rates for Production Runs

Table: Expert personnel for the Level 1 Trigger
Name Extension Date of qualification
Alexander Somov 269-5553 June 20, 2015