Level-1 Trigger Shift

From Hall D Ops Wiki
Revision as of 13:50, 12 February 2017 by Somov (Talk | contribs)

Jump to: navigation, search

Configuration for Production Runs

Production data is taken with the following configuration, which has to be selected at the RCM Run Config GUI:


RUN: EXPERT
SETUP: hd_all.tsg
CONFIG: FCAL_BCAL_PS_m9.conf (main production mode) or
FCAL_BCAL_PS_m10.conf (debug mode, readout raw samples for FADCs 250 and 125)


caption



Trigger Types

1. GTP Triggers

Currently, there are following main (GTP) triggers used in data production:


Trigger Type Trigger Bit (starting from 1)
FCAL + 0.5 BCAL > 0.5 GeV 1
BCAL > 1.1 GeV 3
PS 4

Trigger bits used in spring 2016 are listed in


2. TS Front Pannel Triggers

Several ancllary triggers, which are used to monitr/study detector performance run in parallel to the main production triggers. These triggers are listed below:

FCAL LED trigger: The pulser can be enabled using the FCAL 'css screen. FCAL team can also run an LED pulser script.
BCAL LED trigger The pulser can be enabled using BCAL css screen.
Random Trigger The random trigger can be enabled from the PS css screen.


The bit assignment and typical rates of the TS FP triggers is


Trigger Monitor

Trigger Rates for Production Runs

Table: Expert personnel for the Level 1 Trigger
Name Extension Date of qualification
Alexander Somov 269-5553 June 20, 2015