Level-1 Trigger Shift

From Hall D Ops Wiki
Revision as of 16:58, 12 February 2017 by Somov (Talk | contribs)

Jump to: navigation, search

Configuration for Production Runs

Production data is taken with the following configuration. The configuration has to be selected on the RCM Run Config GUI when you start DAQ using rcm.sh (see descriptions at the DAQ page). Make sure that the following config parameters are set:


RUN: EXPERT
SETUP: hd_all.tsg
CONFIG: FCAL_BCAL_PS_m9.conf (main production mode, used for the data production) or
FCAL_BCAL_PS_m10.conf (debug mode, readout raw samples for FADCs 250 and 125)


caption



Trigger Types

1. GTP Triggers

Currently, the following main Global Trigger Processor (GTP) triggers are used for data production:


Trigger Type Trigger Bit (starting from 1)
FCAL + 0.5 BCAL > 0.5 GeV 1
BCAL > 1.1 GeV 3
PS 4

Trigger bits used in spring 2016 are can be found here.


2. TS Front Pannel Triggers

Several ancillary triggers run in parallel to the main production triggers. These triggers are distributed through the TS front pannel, and are used to monitor/study detector performance. The triggers are listed below:

FCAL LED The pulser can be enabled using the FCAL css screen. FCAL team can also run an LED pulser script, which is currently not controlled through the css.
BCAL LED The pulser can be enabled using BCAL css screen. Usually the pulser script is enabled, which alternate upstream and downstream LEDs for various BCAL collumns.
Random The random trigger can be enabled from the PS css screen.


Assignment of the TS FP trigger bits and typical trigger rates are shown in the table:

Trigger Type Trigger Bit (starting from 1) Typical rate
FCAL LED 3 > 10 Hz
BCAL LED 9, 10 (single or both bits can be seen, depending on the bcal LED script) > 1 Hz
Random 12 50 Hz

Note, all these FP trigger bits are enabled at the TS by default. If you don't see them in data or online using the trig_client monitor, check whether pulsers are enabled in the FCAL/BCAL/PS css screens (contact with the FCAL/BCAL detector representatives).

Trigger Monitor

Trigger rates produced by the detector (generated by the Global Trigger Processor) and also distributed from the TS front pannel can be monitored using trig_client program. To run the program:

  1. Login to the gluon machine under hdops and execute trig_client.
  2. If trig_client is already running, you will get the message on the xterm screen.
To restart the client, kill the process and delete the logfile
/home/hdops/CDAQ/config/hd_server/trig_client.log



Trigger Rates for Production Runs

Table: Expert personnel for the Level 1 Trigger
Name Extension Date of qualification
Alexander Somov 269-5553 June 20, 2015