Difference between revisions of "Shift check-list"
From Hall D Ops Wiki
Line 4: | Line 4: | ||
! width=200px | Date: (mm/dd) !! width=100px | !! width=100px | !! width=100px | | ! width=200px | Date: (mm/dd) !! width=100px | !! width=100px | !! width=100px | | ||
|- | |- | ||
− | | Time (hh/mm, 24:00) || || || | + | | Time (hh/mm, 24:00) || || || |
|- | |- | ||
− | | Your Initials || || || | + | | Your Initials || || || |
|- | |- | ||
− | | Beam Energy (GeV) || || || | + | | Beam Energy (GeV) || || || |
|- | |- | ||
− | | e- Beam Current (uA) || || || | + | | e- Beam Current (uA) || || || |
|- | |- | ||
− | | Radiator (RL) || || || | + | | Radiator (RL) || || || |
|- | |- | ||
− | | Tagger current (A)/field(T) || || || | + | | Tagger current (A)/field(T) || || || |
|- | |- | ||
− | | Solenoid current (A) || || || | + | | Solenoid current (A) || || || |
|- | |- | ||
− | | Solenoid temperature alarms ok? Record He pressure|| || || | + | | Solenoid temperature alarms ok? Record He pressure|| || || |
|- | |- | ||
− | | Target type || || || | + | | Target type || || || |
|- | |- | ||
− | | Collimator aperture (mm) || || || | + | | Collimator aperture (mm) || || || |
|- | |- | ||
− | | All High Voltage ok? check box for BCal, FCal, CDC, FDC, TOF, ST, PS, TagM, TagH) ||<math>\Box</math> <math>\Box</math> <math>\Box</math> <math>\Box</math> <math>\Box</math> <br> <math>\Box</math> <math>\Box</math> <math>\Box</math> <math>\Box</math> || <math>\Box</math> <math>\Box</math> <math>\Box</math> <math>\Box</math> <math>\Box</math> <br> <math>\Box</math> <math>\Box</math> <math>\Box</math> <math>\Box</math> || | + | | All High Voltage ok? check box for BCal, FCal, CDC, FDC, TOF, ST, PS, TagM, TagH) ||<math>\Box</math> <math>\Box</math> <math>\Box</math> <math>\Box</math> <math>\Box</math> <br> <math>\Box</math> <math>\Box</math> <math>\Box</math> <math>\Box</math> || <math>\Box</math> <math>\Box</math> <math>\Box</math> <math>\Box</math> <math>\Box</math> <br> <math>\Box</math> <math>\Box</math> <math>\Box</math> <math>\Box</math> || <math>\Box</math> <math>\Box</math> <math>\Box</math> <math>\Box</math> <math>\Box</math> <br> <math>\Box</math> <math>\Box</math> <math>\Box</math> <math>\Box</math> |
|- | |- | ||
− | | Trigger rate (kHz) || || || | + | | Trigger rate (kHz) || || || |
|- | |- | ||
− | | Trigger file/DAQ config. || || || | + | | Trigger file/DAQ config. || || || |
|- | |- | ||
− | | Pair Spec. current (A) || || || | + | | Pair Spec. current (A) || || || |
|- | |- | ||
− | | Pair Spec. converter (RL) || || || | + | | Pair Spec. converter (RL) || || || |
|- | |- | ||
− | | Visual Halls Inspection || || || | + | | Visual Halls Inspection || || || |
|- | |- | ||
− | | DAQ screens up || || || | + | | DAQ screens up || || || |
|- | |- | ||
− | | Epic summary screen up? || || || | + | | Epic summary screen up? || || || |
|- | |- | ||
− | | Alarm handlers up || || || | + | | Alarm handlers up || || || |
|- | |- | ||
− | | Hall D electronic logbook up || || || | + | | Hall D electronic logbook up || || || |
|- | |- | ||
− | | MCC Epics monitoring screen up || || || | + | | MCC Epics monitoring screen up || || || |
|- | |- | ||
− | | Beam position on profilers OK? (upstrm/dwstrm) || || || | + | | Beam position on profilers OK? (upstrm/dwstrm) || || || |
|- | |- | ||
− | | Beam position on tagger dump viewer || || || | + | | Beam position on tagger dump viewer || || || |
|- | |- | ||
− | | Quadrupole MQPAD00 on? || || || | + | | Quadrupole MQPAD00 on? || || || |
|- | |- | ||
− | | Event display ok? || || || | + | | Event display ok? || || || |
|- | |- | ||
− | | Online monitoring screens up || || || | + | | Online monitoring screens up || || || |
|- | |- | ||
− | | Online monitoring histo ok? || || || | + | | Online monitoring histo ok? || || || |
|- | |- | ||
− | | Ar Gas supply Bank left(psi) || || || | + | | Ar Gas supply Bank left(psi) || || || |
|- | |- | ||
− | | Ar Gas supply Bank right(psi) || || || | + | | Ar Gas supply Bank right(psi) || || || |
|- | |- | ||
− | | CO2 Gas supply Bank left(psi) || || || | + | | CO2 Gas supply Bank left(psi) || || || |
|- | |- | ||
− | | CO2 Gas supply Bank right(psi) || || || | + | | CO2 Gas supply Bank right(psi) || || || |
|- | |- | ||
− | | Alcohol Bubbler top (bubbles?) || || || | + | | Alcohol Bubbler top (bubbles?) || || || |
|- | |- | ||
− | | Alcohol Bubbler bottom (bubbles?) || || || | + | | Alcohol Bubbler bottom (bubbles?) || || || |
|} | |} |
Revision as of 16:25, 16 October 2014
Date: (mm/dd) | |||
---|---|---|---|
Time (hh/mm, 24:00) | |||
Your Initials | |||
Beam Energy (GeV) | |||
e- Beam Current (uA) | |||
Radiator (RL) | |||
Tagger current (A)/field(T) | |||
Solenoid current (A) | |||
Solenoid temperature alarms ok? Record He pressure | |||
Target type | |||
Collimator aperture (mm) | |||
All High Voltage ok? check box for BCal, FCal, CDC, FDC, TOF, ST, PS, TagM, TagH) | |
|
|
Trigger rate (kHz) | |||
Trigger file/DAQ config. | |||
Pair Spec. current (A) | |||
Pair Spec. converter (RL) | |||
Visual Halls Inspection | |||
DAQ screens up | |||
Epic summary screen up? | |||
Alarm handlers up | |||
Hall D electronic logbook up | |||
MCC Epics monitoring screen up | |||
Beam position on profilers OK? (upstrm/dwstrm) | |||
Beam position on tagger dump viewer | |||
Quadrupole MQPAD00 on? | |||
Event display ok? | |||
Online monitoring screens up | |||
Online monitoring histo ok? | |||
Ar Gas supply Bank left(psi) | |||
Ar Gas supply Bank right(psi) | |||
CO2 Gas supply Bank left(psi) | |||
CO2 Gas supply Bank right(psi) | |||
Alcohol Bubbler top (bubbles?) | |||
Alcohol Bubbler bottom (bubbles?) |