Difference between revisions of "Solenoid Operations"

From Hall D Ops Wiki
Jump to: navigation, search
(The Solenoid Magnet)
(Expert On Call)
Line 30: Line 30:
 
== Expert On Call ==
 
== Expert On Call ==
  
The individuals responsible for the operation of the Solenoid are shown in the following table.
+
The individuals responsible for the operation of the Solenoid are shown in the following table. Additional experts may be trained by the system owner and their name and date added to this table.
 
+
 
{| border=1  
 
{| border=1  
 
|+ Table:  Expert personnel for the Solenoid Magnet
 
|+ Table:  Expert personnel for the Solenoid Magnet

Revision as of 07:29, 18 June 2014

The Solenoid Magnet

The principle analysis magnet for the GlueX spectrometer is a superconducting solenoid made from the Large Aperture Solenoid Spectrometer (LASS) solenoid built at Stanford Linear Accelerator Center (SLAC) in 1971. The LASS solenoid consists of four separate coils located in separated vacuum vessels. Three coils were later used a second time for the Muon decays into Electron and GAmma ray (MEGA) experiment at Los Alamos National Lab from 1993 through 1995. During the MEGA experiment, the coils had electrical shorts and leaks to the insulating vacuum along with deteiorated superinsulation and instrumentation. In order to use them for the GlueX experiment, all four LASS coils have been extensively repaired, refurbished and tested at Jefferson Lab. The four coils were then assembled in Hall-D. The final GlueX solenoid has a bore of 1.85~m and measures 4~m long.

The magnet consists of 4608 windings(turns) of conductor in total. The windings are grouped into 19 sub-coils and distributed in four coils. The conductor is made of two copper bars 7.62~mm wide and about 2~mm thick, with a band of about 1~mm thick NbTi superconductor composite soldered in between them. These double-pancake windings are not insulated at their sides and are separated by a 0.64~mm thick stainless steel band co-wound with the cable, and insulated from the cable on both sides by Mylar bands of 0.2~mm thick.

When powered with the maximum current of 1350~A, the solenoid generates a field close to 2~Tesla in the bore. The full inductance of the solenoid is about 26~H.

Routine Operation

Interlocks

Expert On Call

The individuals responsible for the operation of the Solenoid are shown in the following table. Additional experts may be trained by the system owner and their name and date added to this table.

Table: Expert personnel for the Solenoid Magnet
Name Extension Date of qualification
SC EXPERT ON CALL XXX-XXX June 12, 2014
George Biallas - Solenoid 269-7535 June 12, 2014
Yi Qiang - Solenoid/PXI 269-7237 June 12, 2014
Mark Stevens - Power Supply 269-6383 June 12, 2014
Jonathan Creel - Cryogenics 269-5925 June 12, 2014
Dave Butler - PLC 329-2583 June 12, 2014