Difference between revisions of "Standard Production Running Conditions"

From Hall D Ops Wiki
Jump to: navigation, search
Line 8: Line 8:
 
|-
 
|-
 
| Beam Profiler || in || in
 
| Beam Profiler || in || in
 +
|-
 +
| 5C11B optimal coordinates || x = -1.6 mm, y = +1.0 mm || same as polarized
 
|-
 
|-
 
| Active Collimator optimal coordinates || x = -0.9 mm, y = 0.0 mm || same as polarized  
 
| Active Collimator optimal coordinates || x = -0.9 mm, y = 0.0 mm || same as polarized  

Revision as of 15:34, 1 April 2016

Item Polarized Beam Unpolarized Beam
Beam Current 200 nA 200 nA
Radiator 20 micron diamond, JD70-118 amorphous, 3×10-4
Beam Profiler in in
5C11B optimal coordinates x = -1.6 mm, y = +1.0 mm same as polarized
Active Collimator optimal coordinates x = -0.9 mm, y = 0.0 mm same as polarized
Collimator 3.4 mm 3.4 mm
TPol target Be 750 μm Be 750 μm
Pair Spect. Convertor retracted retracted
Pair Spect. Magnet Current 991 A 991 A
GlueX Solenoid 1200 A 1200 A
TAC retracted retracted