Difference between revisions of "Standard Production Running Conditions"
From Hall D Ops Wiki
Line 9: | Line 9: | ||
| Tagger Quadrupole (MQPAD00) Current || 0 A || 0 A | | Tagger Quadrupole (MQPAD00) Current || 0 A || 0 A | ||
|- | |- | ||
− | | Radiator || 20 micron diamond, JD70- | + | | Radiator || 20 micron diamond, JD70-119 || amorphous, 3×10<sup>-4</sup> |
|- | |- | ||
| Beam Profiler || BEAM || BEAM | | Beam Profiler || BEAM || BEAM |
Revision as of 08:24, 3 April 2016
Item | Polarized Beam | Unpolarized Beam |
---|---|---|
Beam Current | 200 nA | 200 nA |
BPM (IPM5C11B) optimal coordinates | x = -1.6 mm, y = +1.0 mm | same as polarized |
Tagger Quadrupole (MQPAD00) Current | 0 A | 0 A |
Radiator | 20 micron diamond, JD70-119 | amorphous, 3×10-4 |
Beam Profiler | BEAM | BEAM |
Active Collimator optimal coordinates | x = -0.9 mm, y = 0.0 mm | same as polarized |
Collimator | 3.4 mm | 3.4 mm |
TPol target | Be 75 μm | Be 75 μm |
Pair Spect. Convertor | retracted | retracted |
Pair Spect. Magnet Current | 991 A | 991 A |
GlueX Solenoid | 1200 A | 1200 A |
TAC | retracted | retracted |