Item | Polarized Beam | Unpolarized Beam |
---|---|---|
Beam Current | 160 nA | 200 nA |
BPM (IPM5C11B) optimal coordinates | x = -1.6 mm, y = +1.0 mm | same as polarized |
Tagger Quadrupole (MQPAD00) Current | 0 A | 0 A |
Radiator | 20 micron diamond, JD70-119 | amorphous, 3×10-4 |
Beam Profiler | retracted | retracted |
Active Collimator optimal coordinates | x = -0.9 mm, y = 0.0 mm | same as polarized |
Collimator | 3.4 mm | 3.4 mm |
TPol target | Be 75 μm | Be 75 μm |
Pair Spect. Convertor | retracted | retracted |
Pair Spect. Magnet Current | 991 A | 991 A |
GlueX Solenoid | 1200 A | 1200 A |
TAC | retracted | retracted |