Line 7: Line 7:
 
| BPM (IPM5C11B) optimal coordinates || x = -1.6 mm, y = +1.0 mm || same as polarized  
 
| BPM (IPM5C11B) optimal coordinates || x = -1.6 mm, y = +1.0 mm || same as polarized  
 
|-
 
|-
| Tagger Quadrupole Current (MQPAD00) || 0 A || 0 A
+
| Tagger Quadrupole (MQPAD00) Current || 0 A || 0 A
 
|-
 
|-
 
| Radiator || 20 micron diamond, JD70-118 || amorphous, 3&times;10<sup>-4</sup>
 
| Radiator || 20 micron diamond, JD70-118 || amorphous, 3&times;10<sup>-4</sup>

Revision as of 15:44, 1 April 2016

Item Polarized Beam Unpolarized Beam
Beam Current 200 nA 200 nA
BPM (IPM5C11B) optimal coordinates x = -1.6 mm, y = +1.0 mm same as polarized
Tagger Quadrupole (MQPAD00) Current 0 A 0 A
Radiator 20 micron diamond, JD70-118 amorphous, 3×10-4
Beam Profiler in in
Active Collimator optimal coordinates x = -0.9 mm, y = 0.0 mm same as polarized
Collimator 3.4 mm 3.4 mm
TPol target Be 750 μm Be 750 μm
Pair Spect. Convertor retracted retracted
Pair Spect. Magnet Current 991 A 991 A
GlueX Solenoid 1200 A 1200 A
TAC retracted retracted