Start Counter Shift

From Hall D Ops Wiki
Revision as of 16:18, 23 October 2014 by Marki (Talk | contribs) (MPPC bias voltages and amplifier power)

Jump to: navigation, search

Detector Description

The start counter is a scintillator hodoscope surrounding the target region. It consists of 30 identical scintillator counters (each counter thus subtends 36 degrees of azimuth). Each counter has a nose section, and a straight section so that the array as a whole forms a cylinder-like region of about 40 cm, with an radius of about 8 cm, and a downstream nose cone of going down to 2 cm from the beamline at an angle of 18.5 from the cylinder-like region.

Each counter is read out by a set of four 3mmx3mm Hamamatsu MPPCs. These in turn are arranged on 10 circuit boards, each board responsible for three of the counters. Each set of four operates with a common bias voltage. The output of the four MPPCs for a channel is summed and amplified locally. Each channel (set of four) is instrumented with thermisters for temperature monitoring. Cooling is done by forced air at room temperature.

Shift Duties

Shift crews should be monitoring the following:

  1. MPPC bias voltages
  2. amplifier power (low voltage supplies)
  3. statistical information from raw data ("monitoring histograms")

MPPC bias voltages and amplifier power

Both of these classes of voltages are supplied by Weiner MPOD modules. Shift crews should monitor the GUI to insure all channels are on during data taking. The detailed instructions for operating the EPICS slow controls GUIs can be found here. Most important properties of individual bias and low-voltage channels will be monitored automatically by the EPICS alarm system. Shift crews need to respond to alarms as they arise. To facilitate this, each shift a check should be made that the Start Counter MPOD F HV is up and running.

The conditions that may cause EPICS alarms are:

  • tripped voltage
  • read-back voltage out-of-range
  • supply current out-of-range
  • EPICS communication lost

In responding to alarms shift crews should check the guidance for the alarms as provided by the alarm handler.

Statistical Information

Each run produces a set of monitoring histograms that should be compared to nominal histograms and scanned for anomalies. The histograms include:

  • occupancy, channel-by-channel
  • timing distributions
  • amplitude distributions

Expert personnel

The individuals responsible for checking that the Start Counter is ready to take data and setting its operating parameters are shown in following table. Problems with normal operation of the Start Counter should be referred to those individuals and any changes to their settings must be approved by them. Additional experts may be trained by the system owner and their name and date added to this table.

Table: Expert personnel for the Start Counter system
Name Extension Date of qualification
Mark Ito 269-5295 June 12, 2014