Difference between revisions of "Tune Photon Beam"

From Hall D Ops Wiki
Jump to: navigation, search
(Created page with "__TOC__ ==Main Page== ==Tune Electron Beam== ==Tune Photon Beam== ==One Week Pause in Running== ==[[Collect Beam Data for Detector...")
 
Line 2: Line 2:
 
==[[Fall 2014 Commissioning Plan|Main Page]]==
 
==[[Fall 2014 Commissioning Plan|Main Page]]==
 
==[[Tune Electron Beam]]==
 
==[[Tune Electron Beam]]==
==[[Tune Photon Beam]]==
+
==Tune Photon Beam==
 +
# Goal: Tune the photon beam to go through the collimator, the experimental target area, and into the photon beam dump.
 +
# Responsibility: HallD, Accelerator, RadCon.
 +
# Conditions:
 +
#* Tagger hall equipment removed or shielded. This includes the microscope (TAGM) and the electronics.
 +
#* Beam 50nA CW (if possible).
 +
#* Radiator 10<sup>-4</sup> RL.
 +
#* Collimator hole is 3.5mm at nominal beam position.
 +
#* Solenoid on with current ~1000A.
 +
#* GlueX detectors off (except peripheral such as BCAL)
 +
#* No target in place (use air along beamline as target).
 +
# Activities
 +
#* Use the beam profiler to move the photon beam to the hole in the collimator. (Accel, Hall D)
 +
#* Check radiation levels in the collimator cave and HallD. (RadCon)
 +
#* Turn the PS magnet on and install a 10<sup>-3</sup> converter. Tune the PS coarse detectors (Hall D).
 +
#* Use the PS coarse detectors to verify the beam location.
 +
#* Insert a convertor in the PS and leave running with its own trigger throughout the run period.
 +
#* Calibrate the active collimator by scanning (desirable activity). (HallD and Accelerator)
 +
#* Use other detectors (under discussion) to verify the beam position with respect to the beam pipes and the target (if time permits) (Hall D)
 +
#* Turn detectors on slowly, moving in from the peripheral to the center. Monitor the rates and background levels. (Hall D)
 +
#* Insert a thin target at the nominal target position. Set the regular trigger and take data for about 1 shift.
 
==[[One Week Pause in Running]]==
 
==[[One Week Pause in Running]]==
 
==[[Collect Beam Data for Detector Checkout]]==
 
==[[Collect Beam Data for Detector Checkout]]==

Revision as of 10:46, 2 July 2014

Main Page

Tune Electron Beam

Tune Photon Beam

  1. Goal: Tune the photon beam to go through the collimator, the experimental target area, and into the photon beam dump.
  2. Responsibility: HallD, Accelerator, RadCon.
  3. Conditions:
    • Tagger hall equipment removed or shielded. This includes the microscope (TAGM) and the electronics.
    • Beam 50nA CW (if possible).
    • Radiator 10-4 RL.
    • Collimator hole is 3.5mm at nominal beam position.
    • Solenoid on with current ~1000A.
    • GlueX detectors off (except peripheral such as BCAL)
    • No target in place (use air along beamline as target).
  4. Activities
    • Use the beam profiler to move the photon beam to the hole in the collimator. (Accel, Hall D)
    • Check radiation levels in the collimator cave and HallD. (RadCon)
    • Turn the PS magnet on and install a 10-3 converter. Tune the PS coarse detectors (Hall D).
    • Use the PS coarse detectors to verify the beam location.
    • Insert a convertor in the PS and leave running with its own trigger throughout the run period.
    • Calibrate the active collimator by scanning (desirable activity). (HallD and Accelerator)
    • Use other detectors (under discussion) to verify the beam position with respect to the beam pipes and the target (if time permits) (Hall D)
    • Turn detectors on slowly, moving in from the peripheral to the center. Monitor the rates and background levels. (Hall D)
    • Insert a thin target at the nominal target position. Set the regular trigger and take data for about 1 shift.

One Week Pause in Running

Collect Beam Data for Detector Checkout

Optimize Detector Settings

Drift Chamber Alignment

Collect More Regular Data