0000337: Refurbish Danfysik power supply for production running
Refurbish our boards, return Hall C boards, replace other components as needed, get Danfysik techs out here to check everything.
No tags attached.
Issue History
2013-04-03 16:24wolinNew Issue
2013-04-03 16:24wolinWork by outside group for Hall D => No
2013-04-03 16:24wolinEstimated man-weeks => 2
2013-04-03 16:24wolinPercentage complete => 0
2013-04-03 16:24wolinActual man-weeks => 0
2013-04-03 16:24wolinStatusnew => assigned
2013-04-03 16:24wolinAssigned To => wolin
2013-04-03 16:25wolinNote Added: 0000508
2013-04-03 16:25wolinStatusassigned => acknowledged
2013-05-16 17:10wolinNote Added: 0000517
2013-06-14 10:19wolinNote Added: 0000533
2013-06-14 10:20wolinNote Edited: 0000533
2013-06-14 10:21wolinNote Added: 0000534
2013-06-14 10:21wolinStatusacknowledged => feedback
2013-06-25 16:59wolinNote Added: 0000545
2013-07-18 09:13wolinNote Added: 0000553
2013-07-18 09:14wolinNote Added: 0000554

Notes
(0000508)
wolin   
2013-04-03 16:25   
Danfysik techs will be here this summer to work on supplies in other halls. Tim is organizing for them to work on our supply as well.
(0000517)
wolin   
2013-05-16 17:10   
Need to tune for 25H instead of 2H (done for Hall A). Need to program ramp profile to get smooth voltage profile, including no overshoot. Probably need timer to inhibit quench detection when the contacter is first closed for (say) 100 ms.
(0000533)
wolin   
2013-06-14 10:19   
(edited on: 2013-06-14 10:20)
Parts for tuning for 25H on the way from Danfysik. Giles figured out how to program hardware ramp profiles. Dave B will think about doing the same in the PLC.

Note that the hardware has many constraints, including the number of points per profile and the number of profiles stored. The PLC has no constraints. Note that we'll need profiles for ramping up AND down. Further the PLC could generate ramp profiles on the fly based on start/end currents and number of steps, so nothing would need to be stored.

(0000534)
wolin   
2013-06-14 10:21   
Waiting for parts to arrive.
(0000545)
wolin   
2013-06-25 16:59   
Parts here, not sure if we'll install them before or after solenoid test.
(0000553)
wolin   
2013-07-18 09:13   
Since we had innumerable delays in the cryo plant all parts were installed, FPGA programs were updated, etc.
(0000554)
wolin   
2013-07-18 09:14   
We still probably want Danfysik techs to come out and go over the whole power supply.