MantisBT - Hall D Offline | |||||
View Issue Details | |||||
ID | Project | Category | View Status | Date Submitted | Last Update |
0000382 | Hall D Offline | General | public | 2013-09-13 14:05 | 2013-09-13 14:05 |
Reporter | wilevine | ||||
Assigned To | |||||
Priority | normal | Severity | minor | Reproducibility | have not tried |
Status | new | Resolution | open | ||
Platform | OS | OS Version | |||
Summary | 0000382: mcsmear BCAL: DBCALHit should use GeV instead of ADC units for energy | ||||
Description | Currently, mcsmear writes out BCAL hits with energy in pseudo-ADC units rather than in physical units (GeV). This is inconsistent with other detectors and also inconsistent with the new DigiHit scheme, in which the DigiHit objects should use ADC units and the plain Hit objects should use physical units. | ||||
Steps To Reproduce | |||||
Additional Information | |||||
Tags | No tags attached. | ||||
Relationships | |||||
Attached Files | |||||
Issue History | |||||
Date Modified | Username | Field | Change | ||
2013-09-13 14:05 | wilevine | New Issue |