MantisBT

View Issue Details Jump to Notes ] Issue History ] Print ]
IDProjectCategoryView StatusDate SubmittedLast Update
0000376Hall D OfflineGeneralpublic2013-08-07 10:062013-08-07 10:06
Reporterdavidl 
Assigned To 
PrioritynormalSeverityminorReproducibilityN/A
StatusnewResolutionopen 
PlatformOSOS Version
Summary0000376: Modify Start Counter sim-=recon to use separate TDC hit
DescriptionThe Start-counter channels have both fADC250 and F1TDC digitization. The current simulation and reconstruction has only one value for the time. In the real data, these will come as separate digitized values that must be linked together in some class. This should be done at the DSCHit level.

The simulation (hdgeant/mcsmear) needs to be modified to provide a high resolution time and low resolution time corresponding to the F1TDC and fADC250 hits respectively.
TagsNo tags attached.
Attached Files

- Relationships

-  Notes
There are no notes attached to this issue.

- Issue History
Date Modified Username Field Change
2013-08-07 10:06 davidl New Issue


Copyright © 2000 - 2024 MantisBT Team