Difference between revisions of "Resolutions"
From GlueXWiki
m (→Resolutions) |
m (→Resolutions) |
||
Line 108: | Line 108: | ||
| 169 | | 169 | ||
|} | |} | ||
+ | |||
+ | |||
+ | * The difference between high and low is largest for 1-3 mm driftdistances but overall the difference is not that big. | ||
+ | * Gas mixture has a big impact | ||
+ | * We might not have a big enough lever arm: | ||
+ | |||
+ | |||
+ | = To do = | ||
+ | |||
+ | * There is a full simulation of the chamber and results are on there way | ||
+ | * We are testing 80/20 gas right now | ||
+ | * We want to test the same mixture as FDC uses | ||
+ | * We also want to try and add ethane | ||
+ | * Try different timing algorithms | ||
+ | * Find a way to extract the timing resolution directly |
Revision as of 14:02, 10 July 2009
Prelude
- Two gases are used: 70/30 and 90/10 Ar/CO2
- Two fADC clock settings are used: 125 and 200 MHz
- Drift time spectra (DCOG method is used):
- Red line is fit to get absolute minimal drift time
- Best tracking results if extracted minimal drift time + 1 time sample
- Samples per rising edge - 2 extra samples 125 -> 200 MHz
- Time-2-distance relation:
- GARFIELD is used. To get best resolutions out of it:
- 68/32 Ar/CO2 is put in GARFIELD for 70/30 gas
- 89/11 Ar/CO2 is put in GARFIELD for 90/10 gas
- +-6% CO2 can give 100~ns difference
- GARFIELD is used. To get best resolutions out of it:
Resolutions
- Difference in gases - blue line is a model prediction:
- 90/10 worse because shorter drift times.
- Model contains:
- Timing resolution
- accuracy
- diffusion
- Table with resolutions for straw 7 and different clock settings:
- high: with hit removed from tracking
- low: with hit included
Distance from wire [mm] | Resolution (low) [um] | Resolution (high [um] | ||
---|---|---|---|---|
125 MHz | 200 MHz | 125 MHz | 200 MHz | |
0-1 | 388 | 394 | 404 | 396 |
1-2 | 346 | 292 | 346 | 205 |
2-3 | 209 | 191 | 222 | 210 |
3-4 | 142 | 135 | 166 | 165 |
4-5 | 118 | 96 | 164 | 151 |
5-6 | 85 | 88 | 148 | 164 |
6-7 | 67 | 70 | 165 | 174 |
7-8 | 65 | 63 | 158 | 169 |
- The difference between high and low is largest for 1-3 mm driftdistances but overall the difference is not that big.
- Gas mixture has a big impact
- We might not have a big enough lever arm:
To do
- There is a full simulation of the chamber and results are on there way
- We are testing 80/20 gas right now
- We want to test the same mixture as FDC uses
- We also want to try and add ethane
- Try different timing algorithms
- Find a way to extract the timing resolution directly