Difference between revisions of "July 22, 2009 CDC Meeting"

From GlueXWiki
Jump to: navigation, search
(No difference)

Revision as of 10:01, 22 July 2009


  1. Action Items/Decisions from Previous Meeting
  • Discussed high prices for tight tolerance components
  • Checked IDEAL tool and manufacturing in Chicago. No listing
  • Tim to discuss with vendor repair of end plates if hole messed up
  • Carnegie Mellon to use GARFIELD to check electric field around crimp pin insert
  • CMU to look over to see if piece tolerances can be loosened to ± .001 in
    • These are ok for hole position. We had tightened them for gluing purposes.
  • OK if we open end plate to .005 tolerance on hole positions, need to reduce straw diameter to prevent interferences
  • Conductive rubber tubes cover 30% of gas holes - ok
  • Add holes for 1/4 inch survey balls in top downstream plete to match upstream (2 at 90°)
  • CMU to send list of glues
    • Silver Epoxy: Tra-Con TRA-DUCT 2929
    • Scotchweld 190 & 270
  • JLAB to specify glue for rohacel to mylar joint