# Winston cone versus Trapezoidal lightguides: the current setup does not seem to be very robust: it includes a LED plus diffuser on one end of the baby cal and a PMT coupled on the other end via either lightguide using optical grease.  Initial tests showed that trap/wico=0.8.  A horizontal scan showed that max(trap)=max(wico), at different x positions.  The setup needs to be improved, by ensuring that the diffuser system produces more uniform light.
 
# Winston cone versus Trapezoidal lightguides: the current setup does not seem to be very robust: it includes a LED plus diffuser on one end of the baby cal and a PMT coupled on the other end via either lightguide using optical grease.  Initial tests showed that trap/wico=0.8.  A horizontal scan showed that max(trap)=max(wico), at different x positions.  The setup needs to be improved, by ensuring that the diffuser system produces more uniform light.
 
# FCAL block plus Plexiglas test: these are in progress, and a horizontal position scan has been measured.
 
# FCAL block plus Plexiglas test: these are in progress, and a horizontal position scan has been measured.
# Review LED monitoring system
+
# Review LED monitoring system: see [http://argus.phys.uregina.ca/cgi-bin/private/DocDB/ShowDocument?docid=1486 George V's May 2010 presentation] as a reference.
##
+
## Improvements to current design.
 +
### Reduce size to 603 format (18x6 mm<sup>2</sup>).

Revision as of 11:44, 22 September 2010

Teleconference Time: 07:00 CST (Regina) /14:00 GMT+2 (Athens)

  • Direct Polycom point-to-point connection

Items for followup from previous meeting(s)

  1. None

Documents to Review

Tentative Agenda

  1. Winston cone versus Trapezoidal lightguides
  2. FCAL block plus Plexiglas test
  3. Review LED monitoring system

Minutes

Attendees: Christina, George V., Pavlos (Athens), Zisis (Regina)

  1. Winston cone versus Trapezoidal lightguides: the current setup does not seem to be very robust: it includes a LED plus diffuser on one end of the baby cal and a PMT coupled on the other end via either lightguide using optical grease. Initial tests showed that trap/wico=0.8. A horizontal scan showed that max(trap)=max(wico), at different x positions. The setup needs to be improved, by ensuring that the diffuser system produces more uniform light.
  2. FCAL block plus Plexiglas test: these are in progress, and a horizontal position scan has been measured.
  3. Review LED monitoring system: see George V's May 2010 presentation as a reference.
    1. Improvements to current design.
      1. Reduce size to 603 format (18x6 mm2).