− | + | 55Fe events at 80 sccm total, 1850V (left) and 2050V (right) | |
{| border="0" cellpadding="2" | {| border="0" cellpadding="2" | ||
|width="400pt"| | |width="400pt"| | ||
− | [[Image:events_80_1850.png|thumb|400px| | + | [[Image:events_80_1850.png|thumb|400px|ADC contents for accumulated events: 55Fe mixed 50/50 at 1850V]] |
|width="400pt"| | |width="400pt"| | ||
− | [[Image:events_80_2050.png|thumb|400px| | + | [[Image:events_80_2050.png|thumb|400px|ADC contents for accumulated events: 55Fe mixed 50/50 at 2050V]] |
|} | |} | ||
+ | 55Fe events at 40 sccm total, 1850V (left) and 2050V (right); 2000V (far right). | ||
+ | {| border="0" cellpadding="2" | ||
+ | |width="400pt"| | ||
+ | [[Image:events_40_1850.png|thumb|400px|ADC contents for accumulated events: 55Fe mixed 50/50 at 1850V]] | ||
+ | |width="400pt"| | ||
+ | [[Image:events_40_2050.png|thumb|400px|ADC contents for accumulated events: 55Fe mixed 50/50 at 2050V]] | ||
+ | |width="400pt"| | ||
+ | [[Image:events_40_2000.png|thumb|400px|ADC contents for accumulated events: 55Fe mixed 50/50 at 2000V]] | ||
+ | |} | ||
+ | <br> | ||
+ | 55Fe events, zoomed in on pedestal... 80 sccm total, 1850V (left) and 2050V (right) | ||
+ | {| border="0" cellpadding="2" | ||
+ | |width="400pt"| | ||
+ | [[Image:events_80_1850z.png|thumb|400px|ADC contents for accumulated events: 55Fe mixed 50/50 at 1850V]] | ||
+ | |width="400pt"| | ||
+ | [[Image:events_80_2050z.png|thumb|400px|ADC contents for accumulated events: 55Fe mixed 50/50 at 2050V]] | ||
+ | |} | ||
− | + | 55Fe events, 40 sccm total, 1850V (left) and 2050V (right); 2000V (far right). | |
− | + | <br>The little blip at ~ch 250 in the RH plot is an afterpulse, this is less noticeable at 2000V. | |
{| border="0" cellpadding="2" | {| border="0" cellpadding="2" | ||
|width="400pt"| | |width="400pt"| | ||
− | [[Image: | + | [[Image:events_40_1850z.png|thumb|400px|ADC contents for accumulated events: 55Fe mixed 50/50 at 1850V]] |
|width="400pt"| | |width="400pt"| | ||
− | [[Image: | + | [[Image:events_40_2050z.png|thumb|400px|ADC contents for accumulated events: 55Fe mixed 50/50 at 2050V]] |
+ | |width="400pt"| | ||
+ | [[Image:events_40_2000z.png|thumb|400px|ADC contents for accumulated events: 55Fe mixed 50/50 at 2000V]] | ||
|} | |} | ||
− | + | <span style="font-weight:bold">Cosmics</span><br> | |
+ | |||
+ | Cosmics - events at 80 sccm total, 1850V (left) and 2050V (right) | ||
{| border="0" cellpadding="2" | {| border="0" cellpadding="2" | ||
|width="400pt"| | |width="400pt"| | ||
− | [[Image: | + | [[Image:events_cosmics_80_1850.png|thumb|400px|ADC contents for accumulated events: cosmics mixed 50/50 at 1850V]] |
|width="400pt"| | |width="400pt"| | ||
− | [[Image: | + | [[Image:events_cosmics_80_2050.png|thumb|400px|ADC contents for accumulated events: cosmics mixed 50/50 at 2050V]] |
|} | |} | ||
− | + | Cosmics, zoomed in on pedestal - events at 80 sccm total, 1850V (left) and 2050V (right) | |
{| border="0" cellpadding="2" | {| border="0" cellpadding="2" | ||
|width="400pt"| | |width="400pt"| | ||
− | [[Image: | + | [[Image:events_cosmics_80_1850z.png|thumb|400px|ADC contents for accumulated events: cosmics mixed 50/50 at 1850V]] |
+ | |width="400pt"| | ||
+ | [[Image:events_cosmics_80_2050z.png|thumb|400px|ADC contents for accumulated events: cosmics mixed 50/50 at 2050V]] | ||
+ | |} | ||
+ | |||
+ | Laser pollution and Cosmics - events at 40 sccm total, 2050V | ||
+ | {| border="0" cellpadding="2" | ||
|width="400pt"| | |width="400pt"| | ||
− | [[Image: | + | [[Image:events_cosmics_40_2050.png|thumb|400px|ADC contents for accumulated events: cosmics mixed 50/50 at 2050V]] |
|} | |} |
Latest revision as of 10:38, 8 November 2010
55Fe events at 80 sccm total, 1850V (left) and 2050V (right)
55Fe events at 40 sccm total, 1850V (left) and 2050V (right); 2000V (far right).
55Fe events, zoomed in on pedestal... 80 sccm total, 1850V (left) and 2050V (right)
55Fe events, 40 sccm total, 1850V (left) and 2050V (right); 2000V (far right).
The little blip at ~ch 250 in the RH plot is an afterpulse, this is less noticeable at 2000V.
Cosmics
Cosmics - events at 80 sccm total, 1850V (left) and 2050V (right)
Cosmics, zoomed in on pedestal - events at 80 sccm total, 1850V (left) and 2050V (right)
Laser pollution and Cosmics - events at 40 sccm total, 2050V