Difference between revisions of "Mattione Update 10312011"

From GlueXWiki
Jump to: navigation, search
(Created page with "== Procedure == * Fit David's γ σ<sub>t</sub> Improvement: Make dE, θ map * Fit the π<sup>-</sup> & proton BCAL σ<sub>t</sub> vs θ distributions ...")
 
(Procedure)
Line 1: Line 1:
 
== Procedure ==
 
== Procedure ==
 +
* Reconstruct &pi;(1600) -> b1&pi; events with t-slope = 2.0 (was 5.0 for X(2000)) using both the 334 and 1234 segmentations
 +
* Plot &Delta;&beta; vs p for &pi;<sup>+</sup> candidates to see proton, &pi;<sup>+</sup> separation.
 +
 +
=== Details ===
 +
* The 1234 segmentation is not available in the HDGEANT simulation, so the BCAL shower time for the 1234 segmentation was smeared manually during reconstruction
 +
** 1234: The BCAL hit-time smear was disabled in mc_smear
 +
** 1234: The shower time was smeared by: &sigma;<sub>smear</sub> = sqrt(&sigma;<sup>2</sup><sub>t_334</sub> - &sigma;<sup>2</sup><sub>t_334_NoSmear</sub>) * &sigma;<sub>t_1234</sub> / &sigma;<sub>t_334</sub>
 
* Fit David's &gamma; &sigma;<sub>t</sub> Improvement: Make dE, &theta; map
 
* Fit David's &gamma; &sigma;<sub>t</sub> Improvement: Make dE, &theta; map
* Fit the &pi;<sup>-</sup> & proton BCAL &sigma;<sub>t</sub> vs &theta; distributions in dE bins, will apply improvement % to this resolution.  
+
* Fit the &pi;<sup>-</sup> & proton BCAL shower &sigma;<sub>t</sub> vs &theta; distributions in dE bins:
 +
** Both the non-smeared and smeared
 +
will apply improvement % to these resolutions.  
 
* Generate, simulate, smear, and reconstruct &pi;(1600) -> b1&pi; events with t-slope = 2.0 (was 5.0 for X(2000))
 
* Generate, simulate, smear, and reconstruct &pi;(1600) -> b1&pi; events with t-slope = 2.0 (was 5.0 for X(2000))
** For 1234 Segmentation, disabled BCAL hit t-smear in mc_smear, smear reconstructed shower time as a function of dE & &theta during reconstruction to reach improved resolution.  
+
** For 1234 Segmentation, disabled BCAL hit t-smear in mc_smear, smeared reconstructed shower time as a function of dE & &theta during reconstruction to reach improved resolution.  
*** Proton, &pi;<sup>+</sup>'s, &pi;<sup>-</sup>'s all smeared the same
+
*** Proton, &pi;<sup>+</sup>'s, &pi;<sup>-</sup>'s all smeared the same.
* Plot &Delta;&beta; vs p for &pi;<sup>+</sup> candidates to see proton, &pi;<sup>+</sup> separation.
+
  
 
== David's BCAL Photon Time Resolution Studies ==
 
== David's BCAL Photon Time Resolution Studies ==

Revision as of 11:21, 31 October 2011

Procedure

  • Reconstruct π(1600) -> b1π events with t-slope = 2.0 (was 5.0 for X(2000)) using both the 334 and 1234 segmentations
  • Plot Δβ vs p for π+ candidates to see proton, π+ separation.

Details

  • The 1234 segmentation is not available in the HDGEANT simulation, so the BCAL shower time for the 1234 segmentation was smeared manually during reconstruction
    • 1234: The BCAL hit-time smear was disabled in mc_smear
    • 1234: The shower time was smeared by: σsmear = sqrt(σ2t_334 - σ2t_334_NoSmear) * σt_1234 / σt_334
  • Fit David's γ σt Improvement: Make dE, θ map
  • Fit the π- & proton BCAL shower σt vs θ distributions in dE bins:
    • Both the non-smeared and smeared

will apply improvement % to these resolutions.

  • Generate, simulate, smear, and reconstruct π(1600) -> b1π events with t-slope = 2.0 (was 5.0 for X(2000))
    • For 1234 Segmentation, disabled BCAL hit t-smear in mc_smear, smeared reconstructed shower time as a function of dE & &theta during reconstruction to reach improved resolution.
      • Proton, π+'s, π-'s all smeared the same.

David's BCAL Photon Time Resolution Studies

  • γ BCAL σt vs. dE (GeV):
Mattione Update 10242011 BCALPhotonTimeResolution Theta12Degrees.gif
Mattione Update 10242011 BCALPhotonTimeResolution Theta16Degrees.gif
Mattione Update 10242011 BCALPhotonTimeResolution Theta20Degrees.gif
Mattione Update 10312011 BCALPhotonTimeResolution Theta50Degrees.gif
Mattione Update 10242011 BCALPhotonTimeResolution Theta90Degrees.gif


Time Resolution Segmentation Ratio

  • γ BCAL σt_1234 / σt_334 vs. dE (GeV):
Mattione Update 10242011 BCALPhotonTimeResolutionRatio.gif


  • Fits to γ BCAL σt_1234 / σt_334 vs. θ in dE bins:
  • Don't trust fits at low-θ, so linearly-interpolate between 12 and 16 degrees.
Mattione Update 10242011 BCALPhotonTimeResolutionRatio Fits1.gif
Mattione Update 10242011 BCALPhotonTimeResolutionRatio Fits2.gif
Mattione Update 10242011 BCALPhotonTimeResolutionRatio Fits3.gif


BCAL π- 334 Segmentation σt Fits

  • BCAL π- 334 Segmentation σt Fits vs. θ in dE bins:
Mattione Update 10242011 BCALPiMinusSigmaT Fits1.gif
Mattione Update 10242011 BCALPiMinusSigmaT Fits2.gif
Mattione Update 10242011 BCALPiMinusSigmaT Fits3.gif
Mattione Update 10242011 BCALPiMinusSigmaT Fits4.gif
Mattione Update 10242011 BCALPiMinusSigmaT Fits5.gif


X(2000) -> b1pi Events, π+ BCAL Δβ vs p

Δβ = βp - βt = p/sqrt(p*p + m*m) - path/(c*TOF)

  • X(2000) -> b1pi Events, π+ BCAL Δβ vs p, 334 Segmentation:
Mattione Update 10242011 BCALPiPlusDeltaBetaVsP 334Segmentation.gif


  • X(2000) -> b1pi Events, π+ BCAL Δβ vs p, 1234 Segmentation:
Mattione Update 10242011 BCALPiPlusDeltaBetaVsP 1234Segmentation.gif