Difference between revisions of "Mattione Update 10312011"
From GlueXWiki
(→π(1600) -> b1pi Events, π+ BCAL Δβ vs p) |
(→Time Resolution Segmentation Ratio) |
||
Line 39: | Line 39: | ||
* Fits to γ BCAL σ<sub>t_1234</sub> / σ<sub>t_334</sub> vs. θ in dE bins: | * Fits to γ BCAL σ<sub>t_1234</sub> / σ<sub>t_334</sub> vs. θ in dE bins: | ||
* Don't trust fits at low-θ, so linearly-interpolate between 12 and 16 degrees. | * Don't trust fits at low-θ, so linearly-interpolate between 12 and 16 degrees. | ||
+ | {| class="wikitable" | ||
+ | | [[Image:Mattione_Update_10312011_BCALPhotonTimeResolutionRatio_Fits1.gif|thumb|left|400px]] | ||
+ | | [[Image:Mattione_Update_10312011_BCALPhotonTimeResolutionRatio_Fits2.gif|thumb|left|400px]] | ||
+ | | [[Image:Mattione_Update_10312011_BCALPhotonTimeResolutionRatio_Fits3.gif|thumb|left|400px]] | ||
+ | |} | ||
+ | |||
[[Image:Mattione_Update_10312011_BCALPhotonTimeResolutionRatio_Fits1.gif|thumb|left|400px]] | [[Image:Mattione_Update_10312011_BCALPhotonTimeResolutionRatio_Fits1.gif|thumb|left|400px]] | ||
[[Image:Mattione_Update_10312011_BCALPhotonTimeResolutionRatio_Fits2.gif|thumb|left|400px]] | [[Image:Mattione_Update_10312011_BCALPhotonTimeResolutionRatio_Fits2.gif|thumb|left|400px]] |
Revision as of 10:16, 2 November 2011
Contents
- 1 Procedure
- 2 David's BCAL Photon Time Resolution Studies
- 3 Time Resolution Segmentation Ratio
- 4 Summary of BCAL π- & proton 334 Segmentation σt Fits
- 5 BCAL π- 334 Segmentation σt Fits
- 6 BCAL π- 334 Segmentation σt Fits with BCAL Time Smear Disabled
- 7 BCAL Proton 334 Segmentation σt Fits
- 8 BCAL Proton 334 Segmentation σt Fits with BCAL Time Smear Disabled
- 9 π(1600) -> b1pi Events, π+ BCAL Δβ vs p
- 10 LAST WEEK'S RESULT: X(2000) -> b1pi Events, π+ BCAL Δβ vs p
Procedure
- Reconstruct π(1600) -> b1π events with t-slope = 2.0 (was 5.0 for X(2000)) using both the 334 and 1234 segmentations
- Plot Δβ vs p for π+ candidates to see proton, π+ separation.
1234 Segmentation BCAL Time-Smear Details
- The 1234 segmentation is not available in the HDGEANT simulation, so its BCAL shower time was smeared manually during reconstruction
- The BCAL hit-time smear was disabled in mc_smear
- The shower time was smeared by: σsmear = sqrt(σ2t_334 - σ2t_334_NoSmear) * σt_1234 / σt_334
- These time uncertainties were studied as a function of dE and θ
- The σt_1234 / σt_334 ratio was obtained from fitting the results of David Lawrence's studies of photons
- The σ2t_334 and σ2t_334_NoSmear variances were determined separately for protons and pions, by comparing the reconstructed shower times to their true values.
Improvements from last week's study
- Looking at π(1600) -> b1π events with t-slope = 2.0 instead of π(2000) -> b1π events with t-slope = 5.0: Higher proton momentum in BCAL for studying separation
- The σt_334_NoSmear resolution is no longer assumed to be zero: it is non-negligible in the region of the FDC support structure at for large energy deposits (determined separately for protons and pions)
- The σt_334 resolution is determined separately for protons and pions (was using the pion resolution for both previously)
- Better fit to photon σt_1234 / σt_334 distributions due to extra data point at 50 degrees
- Low-θ, low-dE time resolutions better-simulated: instead of extrapolating fit, performing linear-interpolation between data-points.
Issues
- The photon σt_1234 / σt_334 is assumed to be applicable to protons and pions
David's BCAL Photon Time Resolution Studies
- γ BCAL σt vs. dE (GeV):
Time Resolution Segmentation Ratio
- γ BCAL σt_1234 / σt_334 vs. dE (GeV):
- Fits to γ BCAL σt_1234 / σt_334 vs. θ in dE bins:
- Don't trust fits at low-θ, so linearly-interpolate between 12 and 16 degrees.
Summary of BCAL π- & proton 334 Segmentation σt Fits
- When the BCAL time-smear is enabled, the π- & proton time resolutions are similar.
- When the BCAL time-smear is enabled, the π- & proton time resolutions are similar, except at high shower energies.
BCAL π- 334 Segmentation σt Fits
- BCAL π- 334 Segmentation σt Fits vs. θ in dE bins:
- NOTE: For the first dE bin, the values were linearly interpolated between the points instead of fit to a function.
- Last week, the fit was extrapolated from high-θ over the low-θ range.
- NOTE: For the first dE bin, the values were linearly interpolated between the points instead of fit to a function.
BCAL π- 334 Segmentation σt Fits with BCAL Time Smear Disabled
- BCAL π- 334 Segmentation σt Fits with BCAL Time Smear Disabled vs. θ in dE bins:
- NOTE: These resolutions are negligible except at high dE.
- NOTE: The bad fit results were ignored.
- NOTE: For the first two dE bins, the time smear was set to zero.
- NOTE: For the third and forth dE bins, the values were linearly interpolated between the points instead of fit to a function.
BCAL Proton 334 Segmentation σt Fits
- BCAL proton 334 Segmentation σt Fits vs. θ in dE bins:
- NOTE: For the first dE bin, the values were linearly interpolated between the points instead of fit to a function.
- Last week, the π- fit was used, and was extrapolated from high-θ over the low-θ range.
- NOTE: For the first dE bin, the values were linearly interpolated between the points instead of fit to a function.
BCAL Proton 334 Segmentation σt Fits with BCAL Time Smear Disabled
- BCAL proton 334 Segmentation σt Fits vs. θ in dE bins:
- NOTE: These resolutions are negligible except at high dE.
- NOTE: The bad fit results were ignored.
- NOTE: For the first dE bin, the values were linearly interpolated between the points instead of fit to a function.
- NOTE: For the second dE bin, for θ <= 27.0, the values were linearly interpolated between the points. For θ > 27.0, the time resolution was set to zero.
π(1600) -> b1pi Events, π+ BCAL Δβ vs p
Δβ = βp - βt = p/sqrt(p*p + m*m) - path/(c*TOF)
- NOTE: Resolution improvement is worse than last week, presumably due to increased (more realistic) time smearing in 1234 for low-θ, low-dE particles.
- π(1600) -> b1pi Events, π+ BCAL Δβ vs p, 334 Segmentation:
- π(1600) -> b1pi Events, π+ BCAL Δβ vs p, 1234 Segmentation:
- NOTE: Not sure what the source of the kink in the distribution is.
- π(1600) -> b1pi Events, π+ BCAL Δβ vs p, 334 Segmentation at 1.2 GeV/c:
- π(1600) -> b1pi Events, π+ BCAL Δβ vs p, 1234 Segmentation at 1.2 GeV/c:
- π(1600) -> b1pi Events, π+ BCAL Δβ vs p, 334 Segmentation at 1.4 GeV/c:
- π(1600) -> b1pi Events, π+ BCAL Δβ vs p, 1234 Segmentation at 1.4 GeV/c:
- π(1600) -> b1pi Events, π+ BCAL Δβ vs p, 334 Segmentation at 1.5 GeV/c:
- π(1600) -> b1pi Events, π+ BCAL Δβ vs p, 1234 Segmentation at 1.5 GeV/c:
- π(1600) -> b1pi Events, π+ BCAL Δβ vs p, 334 Segmentation at 1.6 GeV/c:
- π(1600) -> b1pi Events, π+ BCAL Δβ vs p, 1234 Segmentation at 1.6 GeV/c:
LAST WEEK'S RESULT: X(2000) -> b1pi Events, π+ BCAL Δβ vs p
Δβ = βp - βt = p/sqrt(p*p + m*m) - path/(c*TOF)
- X(2000) -> b1pi Events, π+ BCAL Δβ vs p, 334 Segmentation:
- X(2000) -> b1pi Events, π+ BCAL Δβ vs p, 1234 Segmentation: