Line 184: | Line 184: | ||
| 11537 | | 11537 | ||
| 1.35 ± 0.04 | | 1.35 ± 0.04 | ||
− | | 1.36 | + | | 1.36 |
| 1.43 ± 0.04 | | 1.43 ± 0.04 | ||
− | | 1.44 | + | | 1.44 |
|} | |} | ||
Line 269: | Line 269: | ||
{| cellpadding="2" border="1" cellspacing="0" | {| cellpadding="2" border="1" cellspacing="0" | ||
− | |+ Integrated signal MPVs and ratios to value for horizontal | + | |+ Integrated signal MPVs and ratios to value for horizontal |
! colspan="2"| Horizontal MPV | ! colspan="2"| Horizontal MPV | ||
! colspan="2"| 30 degrees MPV | ! colspan="2"| 30 degrees MPV | ||
Line 293: | Line 293: | ||
| 9291 | | 9291 | ||
| 10591 | | 10591 | ||
− | | 1.13 | + | | 1.13 ± 0.02 |
| 1.30 | | 1.30 | ||
− | | 1.16 | + | | 1.16 ± 0.02 |
| 1.32 | | 1.32 | ||
|} | |} |
Revision as of 16:06, 14 February 2013
Prototype at 2100V, 50/50 Ar/CO2
The paler lines are fits to a Landau dist, the darker lines are fits to a Landau-Gaussian convolution.
Ratio of MPVs of Landau fit to integration histograms... horizontal : 30deg : 45deg is 5110 : 6620 : 7160 or 1 : 1.29 : 1.40 Ideally this should be 1 : 1.15 : 1.41
Horizontal MPV | 30 degrees MPV | 45 degrees MPV | 30 degrees:horizontal | 45 degrees:horizontal | |||||
---|---|---|---|---|---|---|---|---|---|
Landau | Landau-Gauss | Landau | Landau-Gauss | Landau | Landau-Gauss | Landau | Landau-Gauss | Landau | Landau-Gauss |
218 | 229 | 256 | 264 | 264 | 285 | 1.17 | 1.15 | 1.21 | 1.24 |
Horizontal MPV | 30 degrees MPV | 45 degrees MPV | 30 degrees:horizontal | 45 degrees:horizontal | |||||
---|---|---|---|---|---|---|---|---|---|
Landau | Landau-Gauss | Landau | Landau-Gauss | Landau | Landau-Gauss | Landau | Landau-Gauss | Landau | Landau-Gauss |
5167 | 5301 | 6722 | 7446 | 7163 | 8113 | 1.30 | 1.40 | 1.39 | 1.53 |
The events in the noise peak in the amplitude histo do not reach the integration histo because the code ignores hits with a leading edge gradient less than 1.
Horizontal MPV | 30 degrees MPV | 45 degrees MPV | 30 degrees:horizontal | 45 degrees:horizontal | |||||
---|---|---|---|---|---|---|---|---|---|
Landau | Landau-Gauss | Landau | Landau-Gauss | Landau | Landau-Gauss | Landau | Landau-Gauss | Landau | Landau-Gauss |
281 | 272 | 364 | 335 | 382 | 383 | 1.30 | 1.23 | 1.36 | 1.41 |
Horizontal MPV | 30 degrees MPV | 45 degrees MPV | 30 degrees:horizontal | 45 degrees:horizontal | |||||
---|---|---|---|---|---|---|---|---|---|
Landau | Landau-Gauss | Landau | Landau-Gauss | Landau | Landau-Gauss | Landau | Landau-Gauss | Landau | Landau-Gauss |
8604 | 7986 | 11658 | 10839 | 12339 | 11537 | 1.35 ± 0.04 | 1.36 | 1.43 ± 0.04 | 1.44 |
50/50 premix gas, unfiltered, label reads analysis 49.1 CO2, so this is 51/49 Ar/CO2
2100V with prototype horizontal, scintillators vertical
Estimated max drift time is 650ns
Repeating the tilted measurements just in case the scintillators moved slightly between measurements
File:Run 31989 ampfitz.png zoomed |
File:Run 31989 integfitz.png zoomed |
File:Run 31986 integfitz.png zoomed |
File:Run 31984 integfitz.png zoomed |
The paler lines are fits to a Landau dist, the darker lines are fits to a Landau-Gaussian convolution.
Horizontal MPV | 30 degrees MPV | 45 degrees MPV | 30 degrees:horizontal | 45 degrees:horizontal | |||||
---|---|---|---|---|---|---|---|---|---|
Landau | Landau-Gauss | Landau | Landau-Gauss | Landau | Landau-Gauss | Landau | Landau-Gauss | Landau | Landau-Gauss |
383 | 403 | 394 | 419 | 378 | 413 | 1.03 | 1.04 | 0.99 | 1.02 |
Horizontal MPV | 30 degrees MPV | 45 degrees MPV | 30 degrees:horizontal | 45 degrees:horizontal | |||||
---|---|---|---|---|---|---|---|---|---|
Landau | Landau-Gauss | Landau | Landau-Gauss | Landau | Landau-Gauss | Landau | Landau-Gauss | Landau | Landau-Gauss |
8038 | 7994 | 9049 | 10413 | 9291 | 10591 | 1.13 ± 0.02 | 1.30 | 1.16 ± 0.02 | 1.32 |