For alarms a dedicated MBBI record is implemented with 2 states NO_ALARM and Alarmed. The state itself calculated using CalcOut record. The alarm would be triggered if:
If the channel is in enabled state and { If channel is in neither of the following states: 1. The channel is ramping up and |v0set:fbk - v0set| < ε 2. The channel is on and |v0set:fbk - vmon| < δ and |v0set:fbk - v0set| < ε }
The δ and ε are different parameters for CAEN HV, WIENER LV abd BIAS modules.
CAEN HV | WIENER LV | WIENER BIAS | |
δ | 2V | 0.1V | 0.5V |
ε | 0.01V | 0.01V | 0.01V |