Difference between revisions of "Mar 12, 2015 Calorimetry"
From GlueXWiki
(→Minutes) |
(→Minutes) |
||
Line 68: | Line 68: | ||
##* Need to check that mode 7 data quality is similar to mode 8 running. | ##* Need to check that mode 7 data quality is similar to mode 8 running. | ||
## HV updates for FCAL (Manuel) | ## HV updates for FCAL (Manuel) | ||
− | ##* | + | ##* New EPICS GUI displays 100 pmt voltages at a time (one string). |
+ | ##* Granularity gives better impression of status of FCAL than previous GUI. However, still with several dozen pmts off, most of the FCAL shows red. | ||
+ | ##* At the top right the number of pmts not enabled is listed (typically couple of dozen) and updates regularly. This is currently the best diagnostic of the FCAL status. | ||
+ | ##* A significant problem occurs now that the FCAL Anagate system is connected to EPICS. The EPICS IOC reboots every couple of hours. This in turn causes a couple of pmts to be turned off. The consequence is that over time, many pmts are found off. | ||
+ | ##* Manuel and Hovanes are trying to find the root cause of the reboots. | ||
## Efficiency in BCal Bias Scan (Foda)[http://argus.phys.uregina.ca/gluex/DocDB/0026/002680/001/Efficiency_BCal_Bias_Scan.pdf] | ## Efficiency in BCal Bias Scan (Foda)[http://argus.phys.uregina.ca/gluex/DocDB/0026/002680/001/Efficiency_BCal_Bias_Scan.pdf] | ||
# Reconstruction and Simulation | # Reconstruction and Simulation | ||
Line 79: | Line 83: | ||
##* [http://argus.phys.uregina.ca/cgi-bin/private/DocDB/ShowDocument?docid=2677 GlueX-doc-2677] | ##* [http://argus.phys.uregina.ca/cgi-bin/private/DocDB/ShowDocument?docid=2677 GlueX-doc-2677] | ||
## pi0 and electron calibration (Adesh)[https://halldweb1.jlab.org/wiki/images/0/07/Fcal_gain_calibration_e.pdf] | ## pi0 and electron calibration (Adesh)[https://halldweb1.jlab.org/wiki/images/0/07/Fcal_gain_calibration_e.pdf] | ||
+ | ##* E/p plotted vs p. Select band around E/p~1 as electrons | ||
+ | ##* Elton: Why is the band decreasing toward the minimum ionizing level (looks like E/p and E plots are interchanged)? Not clear. | ||
+ | ##*Take track projections to FCAL and use sum of 25 blocks (e25) surrounding projected impact to use as estimator of shower energy | ||
+ | ##* Use e25/p as a estimator of FCAL gain for blocks within 60 cm of beamline. | ||
+ | ##* These calibration constants were used to check uniformity of LED data and width of pi0 peak. | ||
+ | ##* It appears the new constants improve the quality slightly relative to uncalibrated. | ||
+ | ##* Elton: How does this compare to constants determined by minimizing the pi0 width? Not clear, but will investigate. | ||
+ | ##* Sean: Would like the best set of constants available to the loaded into the dB by tomorrow as baseline for the upcoming run. Adesh will use e25/p gains for inner blocks and LED uniformity gains for outer blocks and load db by tomorrow. | ||
## Pedestals (Tegan) | ## Pedestals (Tegan) | ||
# Any other business | # Any other business |
Revision as of 16:43, 12 March 2015
Contents
Video Conferencing Information
Meeting Time: 11 a.m.
- To join via a Web Browser, go to the page [1] https://bluejeans.com/907185247.
- To join via Polycom room system go to the IP Address: 199.48.152.152 (bjn.vc) and enter the meeting ID: 907185247.
- To join via phone, use one of the following numbers and the Conference ID: 907185247.
- US or Canada: +1 408 740 7256 or
- US or Canada: +1 888 240 2560
- Upon connection all microphones are automatically muted. To unmute your mike on a Polycom or equivalent unit, enter *4. Unmuting on a computer is trivial as there is a microphone button than can be clicked.
- More information on connecting to bluejeans is available.
Participant Direct Lines
- JLab Phone: in CC F326 is 757-269-6460 (usual room)
- JLab Phone in CC L207 is 757-269-7084
- Phone in the Regina Video-conference Suite is 306-585-4204
- Athens Phone: in Christina's office is 011-30-210-727-6947
Action Items
- BCAL pedestals: Tegan (UofR) will summarize the determination of pedestals in a note with plots in preparation for the collaboration meeting.
- Wish-list of action items: discuss attached document (Media:BCAL_Action_Items-2015.pdf) and add chosen items to Wiki page. Zisis will update the list
- Will: Create histograms to determine number of pi0s and pi0 width for online monitoring.
- Work with Hovanes to activate VME LED pulser setup for FCAL (Elton)
References
- FCAL HDFCAL log book
- BCAL HDBCAL log book
Tentative Agenda
- Announcements
- Action Items
- Run conditions
- BCAL temperature, overbias settings (Elton)
- Data with mode8
- HV updates for FCAL (Manuel)
- Efficiency in BCal Bias Scan (Foda)[2]
- Reconstruction and Simulation
- Changes to reconstruction with single-ended hits (Mark)
- Calibration
- Any other business
Minutes
Attendees: Elton, Adesh, Will (L207); Manuel (Hall D); Sean (NW); Zisis, Tegan, Noemi, Ahmed (UofR)
- Announcements
- Accelerator close to delivering 3-beam operation
- Beam loss monitors are currently preventing beam delivery to Hall A at five passes.
- Solenoid is at 1200 A
- Hoping for beam this evening.
- Action Items
- Run conditions
- BCAL temperature, overbias settings (Elton)
- T=10degC for chiller (~11-12 degC on SiPMs), voltage setting for 12 degC, overbias setting is 1.4 V
- Data with mode8. Most data will be taken in mode7.
- Expect to take about 1 hour of mode 8 data per shift
- Need to check that mode 7 data quality is similar to mode 8 running.
- HV updates for FCAL (Manuel)
- New EPICS GUI displays 100 pmt voltages at a time (one string).
- Granularity gives better impression of status of FCAL than previous GUI. However, still with several dozen pmts off, most of the FCAL shows red.
- At the top right the number of pmts not enabled is listed (typically couple of dozen) and updates regularly. This is currently the best diagnostic of the FCAL status.
- A significant problem occurs now that the FCAL Anagate system is connected to EPICS. The EPICS IOC reboots every couple of hours. This in turn causes a couple of pmts to be turned off. The consequence is that over time, many pmts are found off.
- Manuel and Hovanes are trying to find the root cause of the reboots.
- Efficiency in BCal Bias Scan (Foda)[5]
- BCAL temperature, overbias settings (Elton)
- Reconstruction and Simulation
- Changes to reconstruction with single-ended hits (Mark)
- Calibration
- Feb LED runs (Noemi)[6]
- pi0 calibration (Will)
- Amount of data needed for calibration (Elton)
- pi0 and electron calibration (Adesh)[7]
- E/p plotted vs p. Select band around E/p~1 as electrons
- Elton: Why is the band decreasing toward the minimum ionizing level (looks like E/p and E plots are interchanged)? Not clear.
- Take track projections to FCAL and use sum of 25 blocks (e25) surrounding projected impact to use as estimator of shower energy
- Use e25/p as a estimator of FCAL gain for blocks within 60 cm of beamline.
- These calibration constants were used to check uniformity of LED data and width of pi0 peak.
- It appears the new constants improve the quality slightly relative to uncalibrated.
- Elton: How does this compare to constants determined by minimizing the pi0 width? Not clear, but will investigate.
- Sean: Would like the best set of constants available to the loaded into the dB by tomorrow as baseline for the upcoming run. Adesh will use e25/p gains for inner blocks and LED uniformity gains for outer blocks and load db by tomorrow.
- Pedestals (Tegan)
- Any other business