<h2>Run 2577</h2>
 
<h2>Run 2577</h2>
 
10 March 2015. 1 day after changing the gas mixer MFCs from master/slave to independent.  For this run the readout window is different from that in all the others.
 
10 March 2015. 1 day after changing the gas mixer MFCs from master/slave to independent.  For this run the readout window is different from that in all the others.
 +
{| border="0" cellpadding="2"
 +
|+ Hit thresholds 180-100-25, window 64-170
 +
|-
 +
|[[Image:cdc_run2577_t30.png|thumb|x200px|Drift time fit straws with param 6 < 30]]
 +
|[[Image:cdc_run2577_t30z.png|thumb|x200px|zoomed in]]
 +
|[[Image:cdc_run2577_amp.png|thumb|x200px|max amplitude - pedestal]]
 +
|[[Image:cdc_run2577_ped.png|thumb|x200px|pedestal]]
 +
|}
  
 
<h2>Run 2616</h2>
 
<h2>Run 2616</h2>

Revision as of 12:59, 27 March 2015

Fitted drift time function to straws in run 2451, picked straws with tmax slope < 30, used same straws for subsequent runs. Used same hit thresholds & window for all runs.

The drift times are for a small group of straws, the amplitude & pedestal histograms are for ALL straws. In the earlier runs the amplitude histograms are cut off at the lower end by the sparsification threshold so I would not pay too much attention to these. I will look to see if there are any straws with a low enough threshold that the amplitude MPV is visible.


Run 2451

7 Feb 2015. First run of 2015. Increased sparsification thresholds from 7sigma to 18sigma

Hit thresholds 180-100-25, window 44-150
Drift time fit straws with param 6 < 30
zoomed in
max amplitude - pedestal
pedestal

Garfield 5475-4525 Ar-CO2 has tmax ~560ns

Run 2551

2-3 March 2015. 3 weeks after disengaging the alcohol bubbler.

Hit thresholds 180-100-25, window 44-150
Drift time fit straws with param 6 < 30
zoomed in
max amplitude - pedestal
pedestal

Run 2560

8 March 2015. 5 days after changing the CO2 gas factor from 0.773 to 0.74

Hit thresholds 180-100-25, window 44-150
Drift time fit straws with param 6 < 30
zoomed in
max amplitude - pedestal
pedestal

Run 2577

10 March 2015. 1 day after changing the gas mixer MFCs from master/slave to independent. For this run the readout window is different from that in all the others.

Hit thresholds 180-100-25, window 64-170
Drift time fit straws with param 6 < 30
zoomed in
max amplitude - pedestal
pedestal

Run 2616

11 March 2015. 2 days after changing the gas mixer MFCs from master/slave to independent

Hit thresholds 180-100-25, window 44-150
Drift time fit straws with param 6 < 30
zoomed in
max amplitude - pedestal
pedestal

Run 2617

11 March

Hit thresholds 180-100-25, window 44-150
Drift time fit
zoomed in
max amplitude - pedestal
pedestal

Garfield 5200-4800 Ar-CO2 has tmax ~ 595ns

Run 2619

12 March

Hit thresholds 180-100-25, window 44-150
Drift time fit
zoomed in
max amplitude - pedestal
pedestal

Run 2642

14 March. After moving CO2 controller from ch2 to ch4 (on March 13) and decreasing sparsification thresholds

Run 2644

16 March.

Hit thresholds 180-100-25, window 44-150
Drift time fit
zoomed in
max amplitude - pedestal
pedestal

Run 2649

17 March. 10 hours after returning CO2 controller from ch4 to ch2

Hit thresholds 180-100-25, window 44-150
Drift time fit
zoomed in
max amplitude - pedestal
pedestal


Run 2676

22 March.