<h2>Run 2451</h2>
+
<h2>Run 2451 - solenoid off</h2>
 
7 Feb 2015.  First run of 2015.  Increased sparsification thresholds from 7sigma to 18sigma
 
7 Feb 2015.  First run of 2015.  Increased sparsification thresholds from 7sigma to 18sigma
 
{| border="0" cellpadding="2"  
 
{| border="0" cellpadding="2"  
Line 17: Line 17:
 
Garfield 5475-4525 Ar-CO2 has tmax ~560ns
 
Garfield 5475-4525 Ar-CO2 has tmax ~560ns
  
<h2>Run 2551</h2>
+
<h2>Run 2551 - solenoid off</h2>
 
2-3 March 2015. 3 weeks after disengaging the alcohol bubbler.
 
2-3 March 2015. 3 weeks after disengaging the alcohol bubbler.
 
{| border="0" cellpadding="2"  
 
{| border="0" cellpadding="2"  
Line 28: Line 28:
 
|}
 
|}
  
<h2>Run 2560</h2>
+
<h2>Run 2560 - solenoid off</h2>
 
8 March 2015. 5 days after changing the CO2 gas factor from 0.773 to 0.74
 
8 March 2015. 5 days after changing the CO2 gas factor from 0.773 to 0.74
 
{| border="0" cellpadding="2"  
 
{| border="0" cellpadding="2"  
Line 39: Line 39:
 
|}
 
|}
  
<h2>Run 2577</h2>
+
<h2>Run 2577 - solenoid off</h2>
 
10 March 2015. 1 day after changing the gas mixer MFCs from master/slave to independent.  For this run the readout window is different from that in all the others.
 
10 March 2015. 1 day after changing the gas mixer MFCs from master/slave to independent.  For this run the readout window is different from that in all the others.
 
{| border="0" cellpadding="2"  
 
{| border="0" cellpadding="2"  
Line 50: Line 50:
 
|}
 
|}
  
<h2>Run 2616</h2>
+
<h2>Run 2616 - solenoid at 1200A (?) </h2>
 
11 March 2015. 2 days after changing the gas mixer MFCs from master/slave to independent
 
11 March 2015. 2 days after changing the gas mixer MFCs from master/slave to independent
 
{| border="0" cellpadding="2"  
 
{| border="0" cellpadding="2"  
Line 61: Line 61:
 
|}
 
|}
 
   
 
   
<h2>Run 2617</h2>
+
<h2>Run 2617 - solenoid at 1200A</h2>
 
11 March
 
11 March
 
{| border="0" cellpadding="2"  
 
{| border="0" cellpadding="2"  
Line 73: Line 73:
 
Garfield 5200-4800 Ar-CO2 has tmax ~ 595ns
 
Garfield 5200-4800 Ar-CO2 has tmax ~ 595ns
  
<h2>Run 2619</h2>
+
<h2>Run 2619 - solenoid at 1200A</h2>
 
12 March
 
12 March
 
{| border="0" cellpadding="2"  
 
{| border="0" cellpadding="2"  
Line 84: Line 84:
 
|}
 
|}
  
<h2>Run 2642</h2>
+
<h2>Run 2642 - solenoid off</h2>
 
14 March. After moving CO2 controller from ch2 to ch4 (on March 13) and decreasing sparsification thresholds
 
14 March. After moving CO2 controller from ch2 to ch4 (on March 13) and decreasing sparsification thresholds
 
{| border="0" cellpadding="2"  
 
{| border="0" cellpadding="2"  
Line 95: Line 95:
 
|}
 
|}
  
<h2>Run 2644</h2>
+
<h2>Run 2644 - solenoid off</h2>
 
16 March.
 
16 March.
 
{| border="0" cellpadding="2"  
 
{| border="0" cellpadding="2"  
Line 106: Line 106:
 
|}
 
|}
  
<h2>Run 2649</h2>
+
<h2>Run 2649 - solenoid off</h2>
 
17 March.  10 hours after returning CO2 controller from ch4 to ch2
 
17 March.  10 hours after returning CO2 controller from ch4 to ch2
 
{| border="0" cellpadding="2"  
 
{| border="0" cellpadding="2"  
Line 118: Line 118:
  
  
<h2>Run 2676</h2>
+
<h2>Run 2676 - solenoid off</h2>
 
22 March.
 
22 March.

Revision as of 14:00, 27 March 2015

Fitted drift time function to straws in run 2451, picked straws with tmax slope < 30, used same straws for subsequent runs. Used same hit thresholds & window for all runs.

The drift times are for a small group of straws, the amplitude & pedestal histograms are for ALL straws. In the earlier runs the amplitude histograms are cut off at the lower end by the sparsification threshold so I would not pay too much attention to these. I will look to see if there are any straws with a low enough threshold that the amplitude MPV is visible.


Run 2451 - solenoid off

7 Feb 2015. First run of 2015. Increased sparsification thresholds from 7sigma to 18sigma

Hit thresholds 180-100-25, window 44-150
Drift time fit straws with param 6 < 30
zoomed in
max amplitude - pedestal
pedestal

Garfield 5475-4525 Ar-CO2 has tmax ~560ns

Run 2551 - solenoid off

2-3 March 2015. 3 weeks after disengaging the alcohol bubbler.

Hit thresholds 180-100-25, window 44-150
Drift time fit straws with param 6 < 30
zoomed in
max amplitude - pedestal
pedestal

Run 2560 - solenoid off

8 March 2015. 5 days after changing the CO2 gas factor from 0.773 to 0.74

Hit thresholds 180-100-25, window 44-150
Drift time fit straws with param 6 < 30
zoomed in
max amplitude - pedestal
pedestal

Run 2577 - solenoid off

10 March 2015. 1 day after changing the gas mixer MFCs from master/slave to independent. For this run the readout window is different from that in all the others.

Hit thresholds 180-100-25, window 64-170
Drift time fit straws with param 6 < 30
zoomed in
max amplitude - pedestal
pedestal

Run 2616 - solenoid at 1200A (?)

11 March 2015. 2 days after changing the gas mixer MFCs from master/slave to independent

Hit thresholds 180-100-25, window 44-150
Drift time fit straws with param 6 < 30
zoomed in
max amplitude - pedestal
pedestal

Run 2617 - solenoid at 1200A

11 March

Hit thresholds 180-100-25, window 44-150
Drift time fit
zoomed in
max amplitude - pedestal
pedestal

Garfield 5200-4800 Ar-CO2 has tmax ~ 595ns

Run 2619 - solenoid at 1200A

12 March

Hit thresholds 180-100-25, window 44-150
Drift time fit
zoomed in
max amplitude - pedestal
pedestal

Run 2642 - solenoid off

14 March. After moving CO2 controller from ch2 to ch4 (on March 13) and decreasing sparsification thresholds

Hit thresholds 180-100-25, window 44-150
Drift time fit
zoomed in
max amplitude - pedestal
pedestal

Run 2644 - solenoid off

16 March.

Hit thresholds 180-100-25, window 44-150
Drift time fit
zoomed in
max amplitude - pedestal
pedestal

Run 2649 - solenoid off

17 March. 10 hours after returning CO2 controller from ch4 to ch2

Hit thresholds 180-100-25, window 44-150
Drift time fit
zoomed in
max amplitude - pedestal
pedestal


Run 2676 - solenoid off

22 March.