Difference between revisions of "RCDB Standard Searches"
From GlueXWiki
Line 18: | Line 18: | ||
** Subtype: Field Off | ** Subtype: Field Off | ||
*** solenoid_current < 100. | *** solenoid_current < 100. | ||
+ | |||
+ | Corresponding RCDB queris: | ||
+ | <syntaxhighlight lang="python" line="1" > | ||
+ | @is_production = run_type == 'hd_all.tsg' and # Production Run | ||
+ | daq_run == 'PHYSICS' and | ||
+ | beam_current > 2 and | ||
+ | num_events > 10000 and | ||
+ | radiator_id !=5 and | ||
+ | solenoid_current > 100 | ||
+ | |||
+ | @is_cosmic = run_type == 'hd_all.tsg_cosmic' and | ||
+ | 'COSMIC' in daq_run and | ||
+ | beam_current < 1. | ||
+ | |||
+ | @is_empty_target = target_type == "EMPTY & Ready" # Empty Target | ||
+ | |||
+ | @is_amorph_radiator = radiator_id == 0 and target_type == "FULL & Ready" # Amorphous Radiator | ||
+ | |||
+ | @is_coherent_beam = radiator_id != 5 and radiator_id != 0 # Coherent Beam | ||
+ | |||
+ | @is_field_off = solenoid_current < 100 # Field Off | ||
+ | |||
+ | @is_field_on = solenoid_current >= 100 # Field On | ||
+ | |||
+ | @status_approved = status == 1 | ||
+ | |||
+ | @status_unchecked = status == -1 | ||
+ | |||
+ | @status_reject = status == 0 | ||
+ | |||
+ | </syntaxhighlight> | ||
Revision as of 14:21, 18 February 2016
Goal: Classify and search for non-DAQ test runs
- Type: Production Run
- run_type == hd_all.tsg
- daq_run == PHYSICS
- beam_current > 2.
- num_events > 10000
- radiator id !=5 # NOT RETRACTED
- solenoid_current > 100. (?)
- Subtype: Empty Target
- target_type == "EMPTY & Ready"
- Subtype: Amorphous Radiator
- radiator_id = 0
- target_type == "FULL & Ready"
- Subtype: Coherent Beam
- radiator_id != 5 AND radiator_id != 0.
- target_type == "FULL & Ready"
- Subtype: Field Off
- solenoid_current < 100.
Corresponding RCDB queris:
@is_production = run_type == 'hd_all.tsg' and # Production Run
daq_run == 'PHYSICS' and
beam_current > 2 and
num_events > 10000 and
radiator_id !=5 and
solenoid_current > 100
@is_cosmic = run_type == 'hd_all.tsg_cosmic' and
'COSMIC' in daq_run and
beam_current < 1.
@is_empty_target = target_type == "EMPTY & Ready" # Empty Target
@is_amorph_radiator = radiator_id == 0 and target_type == "FULL & Ready" # Amorphous Radiator
@is_coherent_beam = radiator_id != 5 and radiator_id != 0 # Coherent Beam
@is_field_off = solenoid_current < 100 # Field Off
@is_field_on = solenoid_current >= 100 # Field On
@status_approved = status == 1
@status_unchecked = status == -1
@status_reject = status == 0
- status flag
- unchecked = -1
- rejected = 0
- approved = 1
- Type: Cosmic run
- run_type == hd_all.tsg_cosmic
- daq_run == COSMIC*
- beam_current < 1.
- Subtype: Magnet off
- solenoid_current < 100.
- Subtype: Magnet on
- solenoid_current > 100.
- Other types?
- Normalization run (super-low-current, tagger trigger, TAC in, definitions need input from Somov)
- PS-only? (needs input from Somov)
- LED Pulser only?