Difference between revisions of "RCDB Conditions Help"
From GlueXWiki
(Created page with " {| class="wikitable" ! Condition Name !! EPICS variable !! Notes |- | beam_current || IBCAD00CRCUR6 || Beam current from electron dump (?) BCM, averaged over run, in nA |-...") |
(Added polarimeter_converter condition) |
||
(One intermediate revision by one other user not shown) | |||
Line 1: | Line 1: | ||
− | + | This page gives definitions of the condition variables stored in the RCDB as of RunPeriod-2016-02. | |
{| class="wikitable" | {| class="wikitable" | ||
Line 14: | Line 14: | ||
| luminosity || N/A || For future use | | luminosity || N/A || For future use | ||
|- | |- | ||
− | | ps_converter || hd:converter_at_[home,a,b,c] || | + | | ps_converter || hd:converter_at_[home,a,b,c] || 5 x 10<sup>-3</sup> RL, 1 x 10<sup>-3</sup> RL, 3 x 10<sup>-4</sup> RL, Retracted |
|- | |- | ||
| solenoid_current || HallD-PXI:Data:I_Shunt || Measured current in solenoid magnet, in A | | solenoid_current || HallD-PXI:Data:I_Shunt || Measured current in solenoid magnet, in A | ||
Line 20: | Line 20: | ||
| status || N/A || For future use | | status || N/A || For future use | ||
|- | |- | ||
− | | radiator_index || HD:GONI:RADIATOR_INDEX || Goniometer radiator position index, as described [https://halldsvn.jlab.org/repos/trunk/controls/epics/app/goniApp/Db/goni.substitutions | + | | radiator_index || HD:GONI:RADIATOR_INDEX || Goniometer radiator position index, as described [https://halldsvn.jlab.org/repos/trunk/controls/epics/app/goniApp/Db/goni.substitutions in this page]. |
|- | |- | ||
− | | radiator_id || HD:GONI:RADIATOR_ID || Goniometer radiator unique ID, as described [https://halldsvn.jlab.org/repos/trunk/controls/epics/app/goniApp/Db/goni.substitutions | + | | radiator_id || HD:GONI:RADIATOR_ID || Goniometer radiator unique ID, as described [https://halldsvn.jlab.org/repos/trunk/controls/epics/app/goniApp/Db/goni.substitutions in this page]. |
|- | |- | ||
| polarization_direction || HD:CBREM:PLANE || Direction of the photon beam linear polarization with respect to the floor: PARA, PERP, or UNKNOWN | | polarization_direction || HD:CBREM:PLANE || Direction of the photon beam linear polarization with respect to the floor: PARA, PERP, or UNKNOWN | ||
|- | |- | ||
− | | radiator_type || Goniometer radiator name, as described [https://halldsvn.jlab.org/repos/trunk/controls/epics/app/goniApp/Db/goni.substitutions | + | | radiator_type || HD:GONI:RADIATOR_NAME OR hd:radiator_at_[a,b,c] || Goniometer radiator name, as described [https://halldsvn.jlab.org/repos/trunk/controls/epics/app/goniApp/Db/goni.substitutions in this page], Amorphous radiator (2 x 10<sup>-5</sup> RL, 1 x 10<sup>-4</sup> RL, 3 x 10<sup>-4</sup> RL), or retracted |
|- | |- | ||
| target_type || HLD:TGT:status || Status of LH2 target: OFF, Cooling, Filling, FULL & Ready, Emptying, EMPTY & Ready | | target_type || HLD:TGT:status || Status of LH2 target: OFF, Cooling, Filling, FULL & Ready, Emptying, EMPTY & Ready | ||
+ | |- | ||
+ | | polarimeter_converter || hd:polarimeter_at_* || Polarimeter's converter. Values: RETRACTED/Be 50um/Be 75um/Be 750um | ||
|} | |} | ||
Latest revision as of 15:20, 29 February 2016
This page gives definitions of the condition variables stored in the RCDB as of RunPeriod-2016-02.
Condition Name | EPICS variable | Notes |
---|---|---|
beam_current | IBCAD00CRCUR6 | Beam current from electron dump (?) BCM, averaged over run, in nA |
beam_energy | HALLD:p | Measured electron beam energy, in GeV |
coherent_peak | HD:CBREM:REQ_EDGE | Requested high-energy edge of the coherent peak, in GeV |
collimator_diameter | hd:collimator_at_[block,a,b] | 5 mm, 3.4 mm, blocking |
luminosity | N/A | For future use |
ps_converter | hd:converter_at_[home,a,b,c] | 5 x 10-3 RL, 1 x 10-3 RL, 3 x 10-4 RL, Retracted |
solenoid_current | HallD-PXI:Data:I_Shunt | Measured current in solenoid magnet, in A |
status | N/A | For future use |
radiator_index | HD:GONI:RADIATOR_INDEX | Goniometer radiator position index, as described in this page. |
radiator_id | HD:GONI:RADIATOR_ID | Goniometer radiator unique ID, as described in this page. |
polarization_direction | HD:CBREM:PLANE | Direction of the photon beam linear polarization with respect to the floor: PARA, PERP, or UNKNOWN |
radiator_type | HD:GONI:RADIATOR_NAME OR hd:radiator_at_[a,b,c] | Goniometer radiator name, as described in this page, Amorphous radiator (2 x 10-5 RL, 1 x 10-4 RL, 3 x 10-4 RL), or retracted |
target_type | HLD:TGT:status | Status of LH2 target: OFF, Cooling, Filling, FULL & Ready, Emptying, EMPTY & Ready |
polarimeter_converter | hd:polarimeter_at_* | Polarimeter's converter. Values: RETRACTED/Be 50um/Be 75um/Be 750um |
Other Notes
- When the nA BPMs are calibrated, we could use another variable for the beam current that might be more accurate for lower (<1 uA) currents, e.g. IPM5C11.VAL,IPM5C11A.VAL,IPM5C11B.VAL,IPM5C11C.VAL