|+ Discrepancies between CDC firmware output and emulation output, evio ok = y means no crashes or other errors
+
|+ Discrepancies between CDC firmware output and emulation output, repeatfree=no repeated pairs
 
|Run  || hits || repeatfree hits || diffs ||time    || q || pedestal || amplitude || integral || overflow count || readout ||
 
|Run  || hits || repeatfree hits || diffs ||time    || q || pedestal || amplitude || integral || overflow count || readout ||
 
|-
 
|-
Line 10: Line 10:
 
|-
 
|-
 
|}
 
|}
 +
NB hits with repeated pairs are not necessarily an error, it was just simpler to exclude all of them

Revision as of 13:29, 17 March 2016

Discrepancies between CDC firmware output and emulation output, repeatfree=no repeated pairs
Run hits repeatfree hits diffs time q pedestal amplitude integral overflow count readout
10954 28658293 24179315 12394 61 0 1 12326 6 0 CDC
10956 87414131 73914777 145176 107559 275 4 37530 12672 0 CDC
10957 19196556 16340197 33186 24069 59 3 9086 2868 0 CDC & FDC