Difference between revisions of "Mattione Update 05162012"
From GlueXWiki
(→π- Resolution Comparison) |
|||
(3 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | == π- | + | == π- Reconstruction Efficiency == |
* # Reconstructed Tracks / Event (for time & wire based, can include "proton" guesses (tried to disable)): | * # Reconstructed Tracks / Event (for time & wire based, can include "proton" guesses (tried to disable)): | ||
** NOTE: Hit selectors disabled for wire based & time based fits | ** NOTE: Hit selectors disabled for wire based & time based fits | ||
Line 9: | Line 9: | ||
== π- Resolution Comparison == | == π- Resolution Comparison == | ||
− | * Track Reconstruction Resolution Comparison (Candidate vs. Time-Based): | + | === 90 Degrees === |
+ | * Track Reconstruction Resolution Comparison (Candidate vs. Time-Based): P = 110, 150, 210 (rows), delta-p, theta, phi (columns) | ||
** NOTE: Plots require closest reconstructed track to be of correct PID (PID: mass set during kalman filter) | ** NOTE: Plots require closest reconstructed track to be of correct PID (PID: mass set during kalman filter) | ||
** NOTE: Ignore the offset in the track-candidate delta-phi distribution | ** NOTE: Ignore the offset in the track-candidate delta-phi distribution | ||
Line 24: | Line 25: | ||
| [[Image:Mattione_Update_05162012_DeltaThetaComparison_PiPlus_SpiralCode_210MeV90Deg.gif|thumb|left|350px|Candidates: 98%, Time-based: 91%]] | | [[Image:Mattione_Update_05162012_DeltaThetaComparison_PiPlus_SpiralCode_210MeV90Deg.gif|thumb|left|350px|Candidates: 98%, Time-based: 91%]] | ||
| [[Image:Mattione_Update_05162012_DeltaPhiComparison_PiPlus_SpiralCode_210MeV90Deg.gif|thumb|left|350px|Candidates: 98%, Time-based: 91%]] | | [[Image:Mattione_Update_05162012_DeltaPhiComparison_PiPlus_SpiralCode_210MeV90Deg.gif|thumb|left|350px|Candidates: 98%, Time-based: 91%]] | ||
+ | |} | ||
+ | |||
+ | === 60 Degrees === | ||
+ | * Track Reconstruction Resolution Comparison (Candidate vs. Time-Based): P = 110, 150, 210 (rows), delta-p, theta, phi (columns) | ||
+ | ** NOTE: Plots require closest reconstructed track to be of correct PID (PID: mass set during kalman filter) | ||
+ | ** NOTE: Ignore the offset in the track-candidate delta-phi distribution | ||
+ | {| class="wikitable" | ||
+ | | [[Image:Mattione_Update_05162012_DeltaPComparison_PiPlus_SpiralCode_110MeV60Deg.gif|thumb|left|350px|Candidates: 92%, Time-based: 38%]] | ||
+ | | [[Image:Mattione_Update_05162012_DeltaThetaComparison_PiPlus_SpiralCode_110MeV60Deg.gif|thumb|left|350px|Candidates: 92%, Time-based: 38%]] | ||
+ | | [[Image:Mattione_Update_05162012_DeltaPhiComparison_PiPlus_SpiralCode_110MeV60Deg.gif|thumb|left|350px|Candidates: 92%, Time-based: 38%]] | ||
+ | |- | ||
+ | | [[Image:Mattione_Update_05162012_DeltaPComparison_PiPlus_SpiralCode_150MeV60Deg.gif|thumb|left|350px|Candidates: 95%, Time-based: 34%]] | ||
+ | | [[Image:Mattione_Update_05162012_DeltaThetaComparison_PiPlus_SpiralCode_150MeV60Deg.gif|thumb|left|350px|Candidates: 95%, Time-based: 34%]] | ||
+ | | [[Image:Mattione_Update_05162012_DeltaPhiComparison_PiPlus_SpiralCode_150MeV60Deg.gif|thumb|left|350px|Candidates: 95%, Time-based: 34%]] | ||
+ | |- | ||
+ | | [[Image:Mattione_Update_05162012_DeltaPComparison_PiPlus_SpiralCode_210MeV60Deg.gif|thumb|left|350px|Candidates: 97%, Time-based: 80%]] | ||
+ | | [[Image:Mattione_Update_05162012_DeltaThetaComparison_PiPlus_SpiralCode_210MeV60Deg.gif|thumb|left|350px|Candidates: 97%, Time-based: 80%]] | ||
+ | | [[Image:Mattione_Update_05162012_DeltaPhiComparison_PiPlus_SpiralCode_210MeV60Deg.gif|thumb|left|350px|Candidates: 97%, Time-based: 80%]] | ||
|} | |} |
Latest revision as of 14:05, 16 May 2012
π- Reconstruction Efficiency
- # Reconstructed Tracks / Event (for time & wire based, can include "proton" guesses (tried to disable)):
- NOTE: Hit selectors disabled for wire based & time based fits
π- Resolution Comparison
90 Degrees
- Track Reconstruction Resolution Comparison (Candidate vs. Time-Based): P = 110, 150, 210 (rows), delta-p, theta, phi (columns)
- NOTE: Plots require closest reconstructed track to be of correct PID (PID: mass set during kalman filter)
- NOTE: Ignore the offset in the track-candidate delta-phi distribution
60 Degrees
- Track Reconstruction Resolution Comparison (Candidate vs. Time-Based): P = 110, 150, 210 (rows), delta-p, theta, phi (columns)
- NOTE: Plots require closest reconstructed track to be of correct PID (PID: mass set during kalman filter)
- NOTE: Ignore the offset in the track-candidate delta-phi distribution