Difference between revisions of "Mattione Update 06252012"
From GlueXWiki
(18 intermediate revisions by the same user not shown) | |||
Line 4: | Line 4: | ||
*** φ → K<sup>+</sup>, K<sup>-</sup> | *** φ → K<sup>+</sup>, K<sup>-</sup> | ||
* Final State: p, π<sup>+</sup>, π<sup>-</sup>, K<sup>+</sup>, K<sup>-</sup> | * Final State: p, π<sup>+</sup>, π<sup>-</sup>, K<sup>+</sup>, K<sup>-</sup> | ||
− | * Events Generated using genr8 with: 9 GeV Photons, Γ<sub>Y(2175)</sub> = 61 MeV/c<sup>2</sup>, t-slope = 5.0, 50.0 < Vertex-Z (cm) < 80.0 | + | * ~530,000 Events Generated using genr8 with: 9 GeV Photons, Γ<sub>Y(2175)</sub> = 61 MeV/c<sup>2</sup>, t-slope = 5.0, 50.0 < Vertex-Z (cm) < 80.0 |
+ | * No background generated (all background is from combinatorics) | ||
== Analysis Overview == | == Analysis Overview == | ||
− | * Require the combined FOM for PID (π<sup>+</sup>, π<sup>-</sup>, K<sup>+</sup>, K<sup>-</sup>) be > 1% | + | * For each q = +/- particle in the reaction, all detected q = +/- tracks are tested as to whether or not they are that particle |
− | * Place very loose cuts on the φ invariant mass (0.8 - 1.3) and p missing mass (0.5 - 1.4): reduces # of bogus track combinations to save time / cleanup histograms | + | ** e.g. If a q = + track has PID FOM > 1% for both the π<sup>+</sup> & K<sup>+</sup>: allow both combinations (DO NOT take the best FOM as true!) |
− | * Kinematic Fit: 4-momentum conservation: p missing mass, φ invariant mass | + | * The analysis (cuts/histing/kinfits) is then performed on each possible track combination (events are only cut if every one of their track combinations is cut): |
− | * Require that the confidence level from the kinematic fit be > 1% | + | ** Require the detection of at least 2+ and 2- tracks (proton is treated as missing) |
+ | ** Require the combined FOM for PID (π<sup>+</sup>, π<sup>-</sup>, K<sup>+</sup>, K<sup>-</sup>) be > 1% | ||
+ | ** Place very loose cuts on the φ invariant mass (0.8 - 1.3) and p missing mass (0.5 - 1.4): reduces # of bogus track combinations to save time / cleanup histograms | ||
+ | ** Kinematic Fit: 4-momentum conservation: p missing mass, φ invariant mass | ||
+ | ** Require that the confidence level from the kinematic fit be > 1% | ||
== Thrown Track Parameters == | == Thrown Track Parameters == | ||
Line 27: | Line 32: | ||
== PID == | == PID == | ||
* PID FOM | * PID FOM | ||
− | [[Image:Mattione_Update_06252012_PIDFOM_KPlus.png|left|500px|]] | + | {| class="wikitable" |
− | [[Image:Mattione_Update_06252012_PIDFOM_KMinus.png|left|500px|]] | + | | [[Image:Mattione_Update_06252012_PIDFOM_KPlus.png|left|500px|]] |
− | [[Image:Mattione_Update_06252012_PIDFOM_PiPlus.png|left|500px|]] | + | | [[Image:Mattione_Update_06252012_PIDFOM_KMinus.png|left|500px|]] |
− | [[Image:Mattione_Update_06252012_PIDFOM_PiMinus.png|left|500px|]] | + | |- |
+ | | [[Image:Mattione_Update_06252012_PIDFOM_PiPlus.png|left|500px|]] | ||
+ | | [[Image:Mattione_Update_06252012_PIDFOM_PiMinus.png|left|500px|]] | ||
+ | |} | ||
+ | <br style="clear:both;"/> | ||
+ | |||
+ | == Initial Mass Peaks == | ||
+ | * Initial Mass Peaks | ||
+ | {| class="wikitable" | ||
+ | | [[Image:Mattione_Update_06252012_Mass_Phi.png|thumb|left|400px|φ Invariant Mass]] | ||
+ | | [[Image:Mattione_Update_06252012_Mass_Proton.png|thumb|left|400px|Proton Missing Mass]] | ||
+ | | [[Image:Mattione_Update_06252012_Mass_Y2175.png|thumb|left|400px|Y(2175) Invariant Mass]] | ||
+ | |} | ||
+ | <br style="clear:both;"/> | ||
+ | |||
+ | == Kinematic Fitting Plots == | ||
+ | |||
+ | * Confidence Level | ||
+ | [[Image:Mattione_Update_06252012_ConfidenceLevel.png|left|500px|]] | ||
+ | <br style="clear:both;"/> | ||
+ | |||
+ | * Confidence Level vs. Mass | ||
+ | {| class="wikitable" | ||
+ | | [[Image:Mattione_Update_06252012_ConfidenceLevelVsPhiMass.png|left|500px|]] | ||
+ | | [[Image:Mattione_Update_06252012_ConfidenceLevelVsProtonMass.png|left|500px|]] | ||
+ | |} | ||
+ | <br style="clear:both;"/> | ||
+ | |||
+ | * Pulls (Confidence Level Cut at 10% for histogramming) | ||
+ | ** μ's = ~0.0, σ's = ~1.08 | ||
+ | {| border="1" cellpadding="2" align="left" valign="top" style="text-align:center;" | ||
+ | !width="50"| Track | ||
+ | !width="350"| p<sub>x</sub> Pull | ||
+ | !width="350"| p<sub>y</sub> Pull | ||
+ | !width="350"| p<sub>z</sub> Pull | ||
+ | |- | ||
+ | ! γ | ||
+ | | || || [[Image:Mattione_Update_06252012_Pull_PhotonPz.png|left|350px]] | ||
+ | |- | ||
+ | ! K<sup>+</sup> | ||
+ | | [[Image:Mattione_Update_06252012_Pull_KPlusPx.png|left|350px]] || [[Image:Mattione_Update_06252012_Pull_KPlusPy.png|left|350px]] || [[Image:Mattione_Update_06252012_Pull_KPlusPz.png|left|350px]] | ||
+ | |- | ||
+ | ! K<sup>-</sup> | ||
+ | | [[Image:Mattione_Update_06252012_Pull_KMinusPx.png|left|350px]] || [[Image:Mattione_Update_06252012_Pull_KMinusPy.png|left|350px]] || [[Image:Mattione_Update_06252012_Pull_KMinusPz.png|left|350px]] | ||
+ | |- | ||
+ | ! π<sup>+</sup> | ||
+ | | [[Image:Mattione_Update_06252012_Pull_PiPlusPx.png|left|350px]] || [[Image:Mattione_Update_06252012_Pull_PiPlusPy.png|left|350px]] || [[Image:Mattione_Update_06252012_Pull_PiPlusPz.png|left|350px]] | ||
+ | |- | ||
+ | ! π<sup>-</sup> | ||
+ | | [[Image:Mattione_Update_06252012_Pull_PiMinusPx.png|left|350px]] || [[Image:Mattione_Update_06252012_Pull_PiMinusPy.png|left|350px]] || [[Image:Mattione_Update_06252012_Pull_PiMinusPz.png|left|350px]] | ||
+ | |} | ||
+ | <br style="clear:both;"/> | ||
+ | |||
+ | == Final Mass Peaks == | ||
+ | * Final Mass Peaks | ||
+ | ** The Y(2175) Invariant Mass is calculated using the kinematic fit values of the track 3-momenta. | ||
+ | ** The Y(2175) Invariant Mass is fit to Breit-Wigner over a quadratic background (I couldn't get the Voigtian fits to converge), and has Γ = ~80 MeV/c<sup>2</sup> (as opposed to the generated Γ = 61 MeV/<sup>2</sup>) | ||
+ | * ~18.9 % of all events remaining | ||
+ | {| class="wikitable" | ||
+ | | [[Image:Mattione_Update_06252012_Mass_FinalPhi.png|thumb|left|400px|φ Invariant Mass]] | ||
+ | | [[Image:Mattione_Update_06252012_Mass_FinalProton.png|thumb|left|400px|Proton Missing Mass]] | ||
+ | | [[Image:Mattione_Update_06252012_Mass_FinalY2175.png|thumb|left|400px|Y(2175) Invariant Mass]] | ||
+ | |} | ||
+ | <br style="clear:both;"/> | ||
+ | |||
+ | == Track P & PID Fraction vs. p == | ||
+ | |||
+ | * Track P & PID Fraction vs. p | ||
+ | {| border="1" cellpadding="2" align="left" valign="top" style="text-align:center;" | ||
+ | !width="50"| Track | ||
+ | !width="350"| Thrown Track p | ||
+ | !width="350"| Final Track p | ||
+ | !width="350"| PID % vs p | ||
+ | |- | ||
+ | ! K<sup>+</sup> | ||
+ | | [[Image:Mattione_Update_06252012_ThrownP_KPlus.png|left|350px]] || [[Image:Mattione_Update_06252012_ComboP_KPlus.png|left|350px]] || [[Image:Mattione_Update_06252012_PIDFractionVsP_KPlus.png|left|350px]] | ||
+ | |- | ||
+ | ! K<sup>-</sup> | ||
+ | | [[Image:Mattione_Update_06252012_ThrownP_KMinus.png|left|350px]] || [[Image:Mattione_Update_06252012_ComboP_KMinus.png|left|350px]] || [[Image:Mattione_Update_06252012_PIDFractionVsP_KMinus.png|left|350px]] | ||
+ | |- | ||
+ | ! π<sup>+</sup> | ||
+ | | [[Image:Mattione_Update_06252012_ThrownP_PiPlus.png|left|350px]] || [[Image:Mattione_Update_06252012_ComboP_PiPlus.png|left|350px]] || [[Image:Mattione_Update_06252012_PIDFractionVsP_PiPlus.png|left|350px]] | ||
+ | |- | ||
+ | ! π<sup>-</sup> | ||
+ | | [[Image:Mattione_Update_06252012_ThrownP_PiMinus.png|left|350px]] || [[Image:Mattione_Update_06252012_ComboP_PiMinus.png|left|350px]] || [[Image:Mattione_Update_06252012_PIDFractionVsP_PiMinus.png|left|350px]] | ||
+ | |} | ||
<br style="clear:both;"/> | <br style="clear:both;"/> |
Latest revision as of 14:21, 25 June 2012
Contents
Reaction
- γ p → Y(2175), p
- Y(2175) → π+, π-, φ
- φ → K+, K-
- Y(2175) → π+, π-, φ
- Final State: p, π+, π-, K+, K-
- ~530,000 Events Generated using genr8 with: 9 GeV Photons, ΓY(2175) = 61 MeV/c2, t-slope = 5.0, 50.0 < Vertex-Z (cm) < 80.0
- No background generated (all background is from combinatorics)
Analysis Overview
- For each q = +/- particle in the reaction, all detected q = +/- tracks are tested as to whether or not they are that particle
- e.g. If a q = + track has PID FOM > 1% for both the π+ & K+: allow both combinations (DO NOT take the best FOM as true!)
- The analysis (cuts/histing/kinfits) is then performed on each possible track combination (events are only cut if every one of their track combinations is cut):
- Require the detection of at least 2+ and 2- tracks (proton is treated as missing)
- Require the combined FOM for PID (π+, π-, K+, K-) be > 1%
- Place very loose cuts on the φ invariant mass (0.8 - 1.3) and p missing mass (0.5 - 1.4): reduces # of bogus track combinations to save time / cleanup histograms
- Kinematic Fit: 4-momentum conservation: p missing mass, φ invariant mass
- Require that the confidence level from the kinematic fit be > 1%
Thrown Track Parameters
- p vs θ
PID
- PID FOM
Initial Mass Peaks
- Initial Mass Peaks
Kinematic Fitting Plots
- Confidence Level
- Confidence Level vs. Mass
- Pulls (Confidence Level Cut at 10% for histogramming)
- μ's = ~0.0, σ's = ~1.08
Track | px Pull | py Pull | pz Pull |
---|---|---|---|
γ | |||
K+ | |||
K- | |||
π+ | |||
π- |
Final Mass Peaks
- Final Mass Peaks
- The Y(2175) Invariant Mass is calculated using the kinematic fit values of the track 3-momenta.
- The Y(2175) Invariant Mass is fit to Breit-Wigner over a quadratic background (I couldn't get the Voigtian fits to converge), and has Γ = ~80 MeV/c2 (as opposed to the generated Γ = 61 MeV/2)
- ~18.9 % of all events remaining
Track P & PID Fraction vs. p
- Track P & PID Fraction vs. p
Track | Thrown Track p | Final Track p | PID % vs p |
---|---|---|---|
K+ | |||
K- | |||
π+ | |||
π- |