Beni needs:
1) data acquisition
- 1 VME crate (possibly Camac or Fastbus)
- 1 cpu
- 1-2 ADC charge sensing ADC's
- 1 TDC (optional)
- 1 Trigger Interface
- 1 Computer/software to communicate with crate controller
2) NIM electronics
- 1 Crate
- 2 Discriminators
- 2 Coincidence units
- 1 Gate Generator or Coincidence unit that can be VETOed
- 1 CFD (optional)
3) misc. Electronics
- Oscilloscope
- Digital multimeter with RS232 interface or other electronic readout means
- cables with LEMO connectors and BNC connectors (for delays)
- some BNC-lemo adapters and other BNC and LEMO equipment