Difference between revisions of "FCAL2 Crates"
From GlueXWiki
Line 13: | Line 13: | ||
** D1-2-BOT: 224 channels connected to 14 fadcs | ** D1-2-BOT: 224 channels connected to 14 fadcs | ||
** D1-3-TOP: 252 channels connected to 16 fadcs | ** D1-3-TOP: 252 channels connected to 16 fadcs | ||
+ | |||
+ | [https://halldweb.jlab.org/detectors/fcal2/cables/translation_test.xlsx Translation table] | ||
* '''Wiener crate (LV, MPOD)''' | * '''Wiener crate (LV, MPOD)''' |
Revision as of 09:19, 17 March 2023
Preliminary Calorimeter Layout
- VXS readout crates
- D1-1-TOP: 224 channels connected to 14 fadcs
- D1-1-MID: 224 channels connected to 14 fadcs
- D1-1-BOT: 224 channels connected to 14 fadcs
- D1-2-TOP: 224 channels connected to 14 fadcs
- D1-2-MID: 224 channels connected to 14 fadcs
- D1-2-BOT: 224 channels connected to 14 fadcs
- D1-3-TOP: 252 channels connected to 16 fadcs
- Wiener crate (LV, MPOD)
- D1-3-BOT: 2 MPOD modules
- HV crates
- D1-4-TOP: 12 CAEN modules (48 channels in each)
- D1-4-MID: 12 CAEN modules
- D1-4-BOT: 11 CAEN modules
- Total width of four racks: 127 inches
- Possible location of racks in Hall D