Difference between revisions of "Charged Particle Tracking"
From GlueXWiki
(Added tracking configuration parameters link) |
(Major re-work of the page) |
||
Line 1: | Line 1: | ||
+ | Up to [[Reconstruction Software]] | ||
+ | |||
+ | |||
+ | |||
+ | == Overview == | ||
+ | Here is a page that gathers information on charged particle tracking in general for the Hall-D detector. | ||
+ | |||
+ | == Documentation == | ||
+ | Here are the most recent documents relevant to charged particle tracking: | ||
+ | |||
+ | === Electronics === | ||
+ | * GlueX-doc-967 [http://argus.phys.uregina.ca/cgi-bin/private/DocDB/ShowDocument?docid=967 High Voltage Distribution for the Hall D CDC and FDC Detectors] | ||
+ | * GlueX-doc-966 [http://argus.phys.uregina.ca/cgi-bin/private/DocDB/ShowDocument?docid=966 Low Voltage Distribution for the Hall D CDC and FDC Detectors] | ||
+ | * GlueX-doc-855 [http://argus.phys.uregina.ca/cgi-bin/private/DocDB/ShowDocument?docid=855 Specification Document for FDC/CDC ADC (125 MSPS)] | ||
+ | |||
+ | === Chamber Design === | ||
+ | *[[CDC|Central Drift Chamber wiki page]] | ||
+ | *[[FDC|Forward Drift Chambers wiki page]] | ||
+ | *[[BCAL|Barrel Calorimeter wiki page]] | ||
+ | *[[TOF|Forward Time-of-Flight wiki page]] | ||
+ | * GlueX-doc-866 [http://argus.phys.uregina.ca/cgi-bin/private/DocDB/ShowDocument?docid=866 Design goals for the Hall D detector and subsystems] | ||
+ | * GlueX-doc-737 [http://argus.phys.uregina.ca/cgi-bin/private/DocDB/ShowDocument?docid=737 CDC Design Parameters] | ||
+ | |||
+ | === Software === | ||
+ | *[[Offline Software|Offline Software wiki page]] | ||
+ | * GlueX-doc-956 [http://argus.phys.uregina.ca/cgi-bin/private/DocDB/ShowDocument?docid=956 The Lorentz Effect: Simulation and Reconstruction] | ||
+ | * GlueX-doc-853 [http://argus.phys.uregina.ca/cgi-bin/private/DocDB/ShowDocument?docid=853 GlueX Simulation Geometry Version 4.0] | ||
+ | * GlueX-doc-761 [http://argus.phys.uregina.ca/cgi-bin/private/DocDB/ShowDocument?docid=761 Track Fitting in GlueX: Development Report III] | ||
+ | |||
+ | |||
+ | == Restricted == | ||
+ | [[Private:Motivating the tracking design parameters]] | ||
+ | |||
+ | |||
+ | == Misc == | ||
+ | |||
+ | These links are old and the information needs to be updated | ||
+ | |||
* [[Tracking Configuration Parameters]] | * [[Tracking Configuration Parameters]] | ||
* [[Track Finding/Fitting 2006]] | * [[Track Finding/Fitting 2006]] |
Revision as of 06:11, 6 February 2008
Up to Reconstruction Software
Contents
Overview
Here is a page that gathers information on charged particle tracking in general for the Hall-D detector.
Documentation
Here are the most recent documents relevant to charged particle tracking:
Electronics
- GlueX-doc-967 High Voltage Distribution for the Hall D CDC and FDC Detectors
- GlueX-doc-966 Low Voltage Distribution for the Hall D CDC and FDC Detectors
- GlueX-doc-855 Specification Document for FDC/CDC ADC (125 MSPS)
Chamber Design
- Central Drift Chamber wiki page
- Forward Drift Chambers wiki page
- Barrel Calorimeter wiki page
- Forward Time-of-Flight wiki page
- GlueX-doc-866 Design goals for the Hall D detector and subsystems
- GlueX-doc-737 CDC Design Parameters
Software
- Offline Software wiki page
- GlueX-doc-956 The Lorentz Effect: Simulation and Reconstruction
- GlueX-doc-853 GlueX Simulation Geometry Version 4.0
- GlueX-doc-761 Track Fitting in GlueX: Development Report III
Restricted
Private:Motivating the tracking design parameters
Misc
These links are old and the information needs to be updated