[[Image:fdc_rate_v_wire.jpg|frame|center|A plot of the rate as a function of anode wire number for the most dowstream anode plane (blue), the most upstream anode plane (red), and the average rate (black).]] | [[Image:fdc_rate_v_wire.jpg|frame|center|A plot of the rate as a function of anode wire number for the most dowstream anode plane (blue), the most upstream anode plane (red), and the average rate (black).]] |
Revision as of 16:43, 16 January 2007
Back to Background Rate Studies
Detector Configuration
- Double-Hit Resolution: 250 ns
- Threshold: 1 keV
- Strip Threshold: 5 mV
- Maximum Number of Hits: 100
- Dead Zone Radius: 3.5 cm
Items for Discussion
- Is the maximum number of hits coded into the simulation sufficient for the FDC? If it is applied at the event level, 100 hits is probably not enough.
- How relevant is the increased background as a function of downstream position of the package?
- Does this need to be considered when optimizing package placement?
- Do/Should the dead regions for each package vary in size depending on downstream location?
- Cathode strip readout energy looks to be incorrect?