Difference between revisions of "Private:Trigger Types"
From GlueXWiki
Line 1: | Line 1: | ||
The main installation and trigger activities can be organized into the three main phases: | The main installation and trigger activities can be organized into the three main phases: | ||
− | : ''1. Initial installation phase, where only a few crates with electronics are installed and connected to the sub-detector.'' | + | : '''1. Initial installation phase, where only a few crates with electronics are installed and connected to the sub-detector.''' |
:* Run stand alone DAC for each sub-detector. Start calibration of fadc pedestals, implementing calibration triggers and start tuning trigger parameters | :* Run stand alone DAC for each sub-detector. Start calibration of fadc pedestals, implementing calibration triggers and start tuning trigger parameters | ||
:: 4 TI boards were populated with 4 additional transceivers and can be used as master-TIs handling the clock and trigger distribution for up to 6 crates | :: 4 TI boards were populated with 4 additional transceivers and can be used as master-TIs handling the clock and trigger distribution for up to 6 crates |
Revision as of 11:26, 2 August 2013
The main installation and trigger activities can be organized into the three main phases:
- 1. Initial installation phase, where only a few crates with electronics are installed and connected to the sub-detector.
- Run stand alone DAC for each sub-detector. Start calibration of fadc pedestals, implementing calibration triggers and start tuning trigger parameters
- 4 TI boards were populated with 4 additional transceivers and can be used as master-TIs handling the clock and trigger distribution for up to 6 crates
- One extra transceiver was added to 4 TI boards. They can be used as a master-TI for small sub-systems (like the microscope, SC, PS)
- Final Detector installation
- Use the global trigger distribution (the global trigger and the trigger distribution crates)
- Up to 4 sub-systems can run in parallel sharing the TS (TS partitioning).
- Calibrate DAQ (readout windows, pedestals, thresholds, ...) and trigger parameters (offsets, threshold, etc)
- Detector Calibration with the Beam
Phase I
BCAL
Can run up to 6 crates with the master TI
- Cosmics
- Generated by CTP in each crate. Possibility to generate the trigger for each BCAL module.
- ID of the 'fired' module is sent to the SSP along with the energy sum.
- The trigger is sent from the SSP front pannel to the master TI.
- Algorithm is being implemented into the CTP.
- Pulser
- Initiated by 2 CAEN 1495 board (24 TTL outputs)
- LED pattern programmed through EPICS
- LVDS output is used as an external trigger for the master TI
Detector | Trigger Types | Descriptions | Start Date |
---|---|---|---|
BCAL | Cosmics | Generated by CTP in each crate (for each BCAL module)
Send to SSP and subsequently to master TI </br> |
unknown |