Difference between revisions of "Hall Network Specifications"
From GlueXWiki
m |
m |
||
Line 17: | Line 17: | ||
* ROC's each need an RS232 connection to a terminal server, terminal servers require an Ethernet connection. | * ROC's each need an RS232 connection to a terminal server, terminal servers require an Ethernet connection. | ||
* Each terminal server has xxx ports. | * Each terminal server has xxx ports. | ||
+ | * Need direct fiber link to ROC if max bandwidth > 80 MB/s. | ||
+ | * Switches can uplink 1.25 GBytes/sec. | ||
Line 22: | Line 24: | ||
{| class="wikitable" style="text-align: center;" | {| class="wikitable" style="text-align: center;" | ||
|+Hall Fiber Specifications | |+Hall Fiber Specifications | ||
− | ! align="center"| Rack !! ROC Connections !! Controls Connections !! Max Bandwidth !! Total Bandwidth !! Fiber Bundle !! Comment | + | ! align="center"| Rack !! High-Speed ROC Connections !! Controls Connections !! TS Connections !! Max Single ROC Bandwidth !! Total Bandwidth !! Fiber Bundle !! Switches !! Terminal Servers !! Comment |
|- | |- | ||
− | |T1 || | + | |T1 || 6 || 12 || 6 || <80 MB/s || 151 MB/s || 12 strand || 1 || 1 || Comment |
+ | |- | ||
+ | |U1A || 0 || 7 || 6 || 0 || low || none || 1 || 1 || Use fiber patch cable to connect to xxxx | ||
|- | |- | ||
− | |||
|} | |} |
Revision as of 12:09, 14 October 2013
Below we propose a design for fiber connections between the Rack Room and the Hall, and network switch and terminal server placement.
- Elliott Wolin, Mark Dalton
- 11-Oct-2013
Notes
- Based on 10**8 photons/sec, 200 kHz trigger rate, existing L1 rejection algorithm, block=1 mode, no compression.
- Ethernet port counts from Fernando's rack layouts and information from Dave Butler concerning other controls requirements.
- We own about 15 24-port managed switches with 10 GBit/s fiber uplinks, some being used in EEL building and other places.
- 8-port managed switches with 1 GBit/s fiber uplinks exist.
- Only managed switches (no hubs!) allowed in hall.
- Fibers come in bundles of 12 or 24, 2 fibers needed for one uplink.
- Standard JLab practice is to terminate all fibers in patch panel when bundles installed.
- Bundle/patch panel installation is expensive, can run much cheaper patch fibers from switch in one rack area to patch panel in nearby rack area.
- DAQ crates require two Ethernet connections each, one for the ROC and one for the fan tray.
- ROC's each need an RS232 connection to a terminal server, terminal servers require an Ethernet connection.
- Each terminal server has xxx ports.
- Need direct fiber link to ROC if max bandwidth > 80 MB/s.
- Switches can uplink 1.25 GBytes/sec.
Rack | High-Speed ROC Connections | Controls Connections | TS Connections | Max Single ROC Bandwidth | Total Bandwidth | Fiber Bundle | Switches | Terminal Servers | Comment |
---|---|---|---|---|---|---|---|---|---|
T1 | 6 | 12 | 6 | <80 MB/s | 151 MB/s | 12 strand | 1 | 1 | Comment |
U1A | 0 | 7 | 6 | 0 | low | none | 1 | 1 | Use fiber patch cable to connect to xxxx |