Difference between revisions of "PMT tiles missing after restarting data taking"
From GlueXWiki
(→Solution) |
|||
Line 9: | Line 9: | ||
# Start Coda normally (Configure->Download->Prestart->Start) | # Start Coda normally (Configure->Download->Prestart->Start) | ||
# Call DIRC expert if problem was not resolved. | # Call DIRC expert if problem was not resolved. | ||
+ | |||
+ | = Occupancy of the Issue = |
Revision as of 12:29, 28 January 2020
Description on the Symptoms
After restarting DAQ, the missing tiles can be seen on the occupancy plots on Rootspy (see an example image to the right).
Solution
- Stop the current run.
- Completely restart Coda (by pressing STOP button on the RCM GUI).
- Start Coda normally (Configure->Download->Prestart->Start)
- Call DIRC expert if problem was not resolved.