Difference between revisions of "PMT tiles missing after restarting data taking"
From GlueXWiki
(→Occupancy of the Issue During Operation) |
(→Occupancy of the Issue During Operation) |
||
Line 22: | Line 22: | ||
! Log Entry | ! Log Entry | ||
|- | |- | ||
+ | ! scope=row | 2020 Jan 12, 13:29 | ||
+ | | Yes | ||
+ | | North c1:r4 | ||
+ | | 71633 | ||
+ | | https://logbooks.jlab.org/entry/3774125 | ||
! scope=row | 2020 Jan 27, 15:18 | ! scope=row | 2020 Jan 27, 15:18 | ||
| Yes | | Yes | ||
Line 39: | Line 44: | ||
| 71367 | | 71367 | ||
| https://logbooks.jlab.org/entry/3762186 | | https://logbooks.jlab.org/entry/3762186 | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|} | |} |
Revision as of 15:11, 30 January 2020
Description on the Symptoms
After restarting DAQ, the missing tiles can be seen on the occupancy plots on Rootspy (see an example image to the right). The same missing tile can be observed on the 2D scalar screen too.
Solution
- Stop the current run.
- Completely restart Coda (by pressing STOP button on the RCM GUI).
- Start Coda normally (Configure->Download->Prestart->Start)
- Call DIRC expert if problem was not resolved.
Occupancy of the Issue During Operation
Date | Resolved After DAQ Reboot | Box Tile | Run Effected | Log Entry | |||||
---|---|---|---|---|---|---|---|---|---|
2020 Jan 12, 13:29 | Yes | North c1:r4 | 71633 | https://logbooks.jlab.org/entry/3774125 | 2020 Jan 27, 15:18 | Yes | North c2:r15 | 71595 | https://logbooks.jlab.org/entry/3772139 |
2020 Jan 15, 13:43 | Yes | South c2:r7 | 71397 | https://logbooks.jlab.org/entry/3764225 | |||||
2020 Jan 12, 06:32 | Yes | North c2:r4 | 71367 | https://logbooks.jlab.org/entry/3762186 |