Difference between revisions of "Offline Monitoring Data Validation CPP"

From GlueXWiki
Jump to: navigation, search
(Checklist)
(BCAL: Update with plots from run 100987)
Line 37: Line 37:
  
 
===BCAL===
 
===BCAL===
* Check Occupancy - Reference: [ [https://halldweb.jlab.org/work/halld2/data_monitoring/RunPeriod-2019-11/mon_ver08/Run071724/bcal_occupancy.png link] ]
+
* Check Occupancy - Reference: [ [https://halldweb.jlab.org/work/halld2/data_monitoring/RunPeriod-2022-05/mon_ver01/Run100987/bcal_occupancy.png link] ]
* Check Hit Efficiency - Reference: [ [https://halldweb.jlab.org/work/halld2/data_monitoring/RunPeriod-2019-11/mon_ver08/Run071724/bcal_hist_eff.png link] ]
+
* Check Hit Efficiency - Reference: [ [https://halldweb.jlab.org/work/halld2/data_monitoring/RunPeriod-2022-05/mon_ver01/Run100987/bcal_hist_eff.png link] ]
* Check Recon. BCAL 1 - Reference: [ [https://halldweb.jlab.org/work/halld2/data_monitoring/RunPeriod-2019-11/mon_ver08/Run071724/HistMacro_BCALReconstruction_p1.png link] ]
+
* Check Recon. BCAL 1 - Reference: [ [https://halldweb.jlab.org/work/halld2/data_monitoring/RunPeriod-2022-05/mon_ver01/Run100987/HistMacro_BCALReconstruction_p1.png link] ]
* Check Recon. BCAL 2 - Reference: [ [https://halldweb.jlab.org/work/halld2/data_monitoring/RunPeriod-2019-11/mon_ver08/Run071724/HistMacro_BCALReconstruction_p2.png link] ]
+
* Check Recon. BCAL 2 - Reference: [ [https://halldweb.jlab.org/work/halld2/data_monitoring/RunPeriod-2022-05/mon_ver01/Run100987/HistMacro_BCALReconstruction_p2.png link] ]
* Check BCAL Matching - Reference:  [ [https://halldweb.jlab.org/work/halld2/data_monitoring/RunPeriod-2019-11/mon_ver08/Run071724/HistMacro_Matching_BCAL.png link] ]
+
* Check Recon. BCAL 3 - Reference: [ [https://halldweb.jlab.org/work/halld2/data_monitoring/RunPeriod-2022-05/mon_ver01/Run100987/HistMacro_BCALReconstruction_p3.png link] ]
 +
* Check BCAL Matching - Reference:  [ [https://halldweb.jlab.org/work/halld2/data_monitoring/RunPeriod-2022-05/mon_ver01/Run100987/HistMacro_Matching_BCAL.png link] ]
  
 
<div class="toccolours mw-collapsible mw-collapsed">
 
<div class="toccolours mw-collapsible mw-collapsed">
Line 50: Line 51:
  
 
<html>
 
<html>
<a href="/work/halld2/data_monitoring/RunPeriod-2019-11/mon_ver08/Run071724/bcal_occupancy.png"><img src="/work/halld2/data_monitoring/RunPeriod-2019-11/mon_ver08/Run071724/bcal_occupancy.png" height="200"/></a>
+
<a href="/work/halld2/data_monitoring/RunPeriod-2022-05/mon_ver01/Run100987/bcal_occupancy.png"><img src="/work/halld2/data_monitoring/RunPeriod-2022-05/mon_ver01/Run100987/bcal_occupancy.png" height="200"/></a>
<a href="/work/halld2/data_monitoring/RunPeriod-2019-11/mon_ver08/Run071724/bcal_hist_eff.png"><img src="/work/halld2/data_monitoring/RunPeriod-2019-11/mon_ver08/Run071724/bcal_hist_eff.png" height="200"/></a>
+
<a href="/work/halld2/data_monitoring/RunPeriod-2022-05/mon_ver01/Run100987/bcal_hist_eff.png"><img src="/work/halld2/data_monitoring/RunPeriod-2022-05/mon_ver01/Run100987/bcal_hist_eff.png" height="200"/></a>
<a href="/work/halld2/data_monitoring/RunPeriod-2019-11/mon_ver08/Run071724/HistMacro_BCALReconstruction_p1"><img src="/work/halld2/data_monitoring/RunPeriod-2019-11/mon_ver08/Run071724/HistMacro_BCALReconstruction_p1" height="200"/></a>
+
<a href="/work/halld2/data_monitoring/RunPeriod-2022-05/mon_ver01/Run100987/HistMacro_BCALReconstruction_p1.png"><img src="/work/halld2/data_monitoring/RunPeriod-2022-05/mon_ver01/Run100987/HistMacro_BCALReconstruction_p1.png" height="200"/></a>
<a href="/work/halld2/data_monitoring/RunPeriod-2019-11/mon_ver08/Run071724/HistMacro_BCALReconstruction_p2.png"><img src="/work/halld2/data_monitoring/RunPeriod-2019-11/mon_ver08/Run071724/HistMacro_BCALReconstruction_p2.png" height="200"/></a>
+
<a href="/work/halld2/data_monitoring/RunPeriod-2022-05/mon_ver01/Run100987/HistMacro_BCALReconstruction_p2.png"><img src="/work/halld2/data_monitoring/RunPeriod-2022-05/mon_ver01/Run100987/HistMacro_BCALReconstruction_p2.png" height="200"/></a>
<a href="/work/halld2/data_monitoring/RunPeriod-2019-11/mon_ver08/Run071724/HistMacro_Matching_BCAL.png"><img src="/work/halld2/data_monitoring/RunPeriod-2019-11/mon_ver08/Run071724/HistMacro_Matching_BCAL.png" height="200"/></a>
+
<a href="/work/halld2/data_monitoring/RunPeriod-2022-05/mon_ver01/Run100987/HistMacro_BCALReconstruction_p3.png"><img src="/work/halld2/data_monitoring/RunPeriod-2022-05/mon_ver01/Run100987/HistMacro_BCALReconstruction_p3.png" height="200"/></a>
 +
<a href="/work/halld2/data_monitoring/RunPeriod-2022-05/mon_ver01/Run100987/HistMacro_Matching_BCAL.png"><img src="/work/halld2/data_monitoring/RunPeriod-2022-05/mon_ver01/Run100987/HistMacro_Matching_BCAL.png" height="200"/></a>
 
</html>
 
</html>
 
</div>
 
</div>
Line 71: Line 73:
 
# '''Recon. BCAL 1''':  The histograms are somewhat complicated.  The best is to compare them to a good run (the example above.)  A difference from the example should be flagged.
 
# '''Recon. BCAL 1''':  The histograms are somewhat complicated.  The best is to compare them to a good run (the example above.)  A difference from the example should be flagged.
 
# '''Recon. BCAL 2''':  The histograms are somewhat complicated.  The best is to compare them to a good run (the example above.)  A difference from the example should be flagged.
 
# '''Recon. BCAL 2''':  The histograms are somewhat complicated.  The best is to compare them to a good run (the example above.)  A difference from the example should be flagged.
 +
# '''Recon. BCAL 3''':  The histograms are somewhat complicated.  The best is to compare them to a good run (the example above.)  A difference from the example should be flagged.
 
# '''BCAL Matching''':  These plots are for charged particles that are tracked in the drift chambers and projected to the BCAL. The z position along the BCAL can be calculated using the time difference between upstream and downstream hits and compared to the extrapolated position using the drift chambers.  The histograms are somewhat complicated.  The best is to compare them to a good run (the example above.)  A difference from the example should be flagged.
 
# '''BCAL Matching''':  These plots are for charged particles that are tracked in the drift chambers and projected to the BCAL. The z position along the BCAL can be calculated using the time difference between upstream and downstream hits and compared to the extrapolated position using the drift chambers.  The histograms are somewhat complicated.  The best is to compare them to a good run (the example above.)  A difference from the example should be flagged.
 
## '''BCAL / Track Delta z (cm)''': (z determined from time of up - down hits in BCAL) - (z determined from the extrapolation of tracks in the drift chambers)
 
## '''BCAL / Track Delta z (cm)''': (z determined from time of up - down hits in BCAL) - (z determined from the extrapolation of tracks in the drift chambers)

Revision as of 14:13, 2 November 2023

This page contains the procedure for checking if CPP/NPP production runs are of good quality and can be used for physics analysis.

Procedure

For each production run, do the following:

  • Go to the Offline Run Browser page.
  • Follow the steps outlined in the checklist below.
  • Workers should check each plot for their assigned subsystem and leave notes in the corresponding spreadsheet if any significant deviations are seen
  • On the spreadsheet, enter "Y" in the "Overall Quality" field if all monitoring histograms are acceptable, otherwise enter "N"
  • We will iterate this procedure until the process converges

Expert Actions

  • Certify that each subsystem is okay
  • Set run status in RCDB based on monitoring results
    • (script provided)

Run Statuses

  • -1 - unchecked
  • 0 - rejected (not physics-quality)
  • 1 - approved
  • 2 - approved long/"mode 8" data
  • 3 - calibration / systematic studies

Checklist

Monitoring Spreadsheet

Reference run for 2022-05: 100987

General Notes


BCAL

  • Check Occupancy - Reference: [ link ]
  • Check Hit Efficiency - Reference: [ link ]
  • Check Recon. BCAL 1 - Reference: [ link ]
  • Check Recon. BCAL 2 - Reference: [ link ]
  • Check Recon. BCAL 3 - Reference: [ link ]
  • Check BCAL Matching - Reference: [ link ]
[Expand]

BCAL Reference Plots

[Expand]

BCAL Notes

CDC

  • Check Occupancy - Reference: [ link ]
  • Check Time-to-distance - Reference: [ link ]
  • Check dE/dx - Reference: [ link ]
  • Check Efficiency- Reference: [ link ]
[Expand]

CDC Reference Plots

[Expand]

CDC Notes

FCAL

  • Check Occupancy - Reference: [ link ]
  • Check FCAL Hits 1 - Reference: [ link ]
  • Check FCAL Hits 2 - Reference: [ link ]
  • Check FCAL Clusters 1 - Reference: [ link ]
  • Check FCAL Recon. 1 - Reference: [ link ]
  • Check FCAL Recon. 2 - Reference: [ link ]
  • Check Recon. FCAL Matching - Reference: [ link ]
[Expand]

FCAL Reference Plots

[Expand]

FCAL Notes

FDC

  • Check Package 1 Occupancy - Reference: [ link ]
  • Check Package 2 Occupancy - Reference: [ link ]
  • Check Package 3 Occupancy - Reference: [ link ]
  • Check Package 4 Occupancy - Reference: [ link ]
[Expand]

FDC Reference Plots

[Expand]

FDC Notes


PS

  • Check Occupancy - Reference: [ link ]
  • Check Timing Alignment - Reference: [ link ]
[Expand]

PS Reference Plots

[Expand]

PS Notes


SC

  • Check Occupancy - Reference: [ link ]
  • Check Recon. SC 1 - Reference: [ link ]
  • Check Recon. SC 2 - Reference: [ link ]
  • Check Recon. SC Matching - Reference: [ link ]
[Expand]

SC Reference Plots

[Expand]

SC Notes


TAGH

  • Check Tagger Occupancy - Reference: [ link ]
  • Check TAGH Hits 2 - Reference: [ link ]
[Expand]

TAGH Reference Plots

[Expand]

TAGH Notes


TAGM

  • Check Timing ADC-RF - Reference: [ link ]
  • Check Timing T-ADC - Reference: [ link ]
[Expand]

TAGM Reference Plots

[Expand]

TAGM Notes


TOF

  • Check Occupancy - Reference: [ link ]
  • Check TOF Matching 1 - Reference: [ link ]
  • Check TOF Matching 2 - Reference: [ link ]
[Expand]

TOF Reference Plots

[Expand]

TOF Notes


RF

  • Check timing offsets - Reference: [ link ]
    • Should be centered around zero
[Expand]

RF Reference Plots


Timing

  • Check HLDT Calorimeter Timing - Reference: [ link ]
  • Check HLDT Drift Chamber Timing - Reference: [ link ]
  • Check HLDT PID System Timing - Reference: [ link ]
  • Check HLDT Tagger Timing - Reference: [ link ]
  • Check HLDT Tagger/RF Align 2 - Reference: [ link ]
  • Check HLDT Tagger/SC Align - Reference: [ link ]
  • Check HLDT Track-Matched Timing - Reference: [ link ]
[Expand]

Timing Reference Plots

[Expand]

Timing Notes

Analysis

  • Tracking 1 - [ link ]
  • Tracking 3 - [ link ]
  • Check BCAL pi0 - Reference: [ link ]
  • Check BCAL/FCAL pi0 - Reference: [ link ]
  • Check p+2pi - Reference: [ link ]
  • Check p+3pi - Reference: [ link ]
  • Check p+pi0g - Reference: [ link ]
[Expand]

Analysis Reference Plots

[Expand]

Analysis Notes